Abstract

The plain fin and circular tubes are generally used in heat exchangers of cooling systems. Numerous studies aiming at enhancing the thermal and hydraulic performances of this type of heat exchangers by changing the fin geometries are present in literature. In the present study, thermal and hydraulic performances of the heat exchangers with circular and elliptical tube have been compared using computational fluid dynamic method. Initially, the validation and comparison were done for the obtained data of the finned and circular tube design with respect to the performance results of the finned and circular tube design in the literature. The ellipticity ratios for the staggered arrangements of heat exchangers were changed within the range of b/a = 0.307-1.0. Numerical studies were performed with ANSYS-Fluent software within the range of Re = 750-2850 based on the fin spacing. As a result of the numerical validation studies, all analyses were solved by utilizing the SST k-omega turbulence model yielding closer values to the available studies similar to literature. Colburn factor j, friction factor f, JF values being the efficiency index and normalized j*, f* and JF* values were calculated and presented graphically. Moreover, temperature contours and streamline patterns were visually presented to evaluate the flow structures around the six different arrangements and to explain the physical reasons of pressure drop and heat transfer phenomena. The largest values of the Colburn factor j and the friction factor f known respectively as an indicator of heat transfer and a measure of pressure drop were obtained for the circular-tube-design ratio of b/a = 1.0 when compared to the other arrangements. According to the JF values, which is the efficiency index and the integrated outcome of heat transfer and pressure drop, the best result was obtained for the model with the diameter ratio of b/a = 0.307. Variations of the JF values for the arrangements of b/a = 0.333 and b/a = 0.307 depending on Reynolds numbers were found to be significantly close to each other. Finally, it is demonstrated that elliptical cross-section tubes with a better design in terms of lower pressure drop and less separated flow structures can be preferred in heat exchanger applications in order to provide energy saving. (C) 2019 Elsevier Ltd. All rights reserved.

Description

Keywords

Cfd, Cooling System, Elliptical Tubes, Heat Transfer, Thermal-Hydraulic Performance, Pressure-Drop Characteristics, Air-Side Performance, Membrane Tube Bank, Plate-Fin, Friction Characteristics, Fluid-Flow, Pcm Solidification, Nanoparticles, Vortex, Model

Fields of Science

0202 electrical engineering, electronic engineering, information engineering, 02 engineering and technology

Citation

WoS Q

Scopus Q

OpenCitations Logo
OpenCitations Citation Count
43

Volume

145

Issue

Start Page

118731

End Page

PlumX Metrics
Citations

CrossRef : 47

Scopus : 55

Captures

Mendeley Readers : 48

SCOPUS™ Citations

51

checked on Jul 17, 2026

Web of Science™ Citations

43

checked on Jul 17, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
3.45

Sustainable Development Goals

AFFORDABLE AND CLEAN ENERGY7
AFFORDABLE AND CLEAN ENERGY