Evaluation of Test Field-Based Calibration and Self-Calibration Models of Uav Integrated Compact Cameras

dc.contributor.author Kazar, Gülüstan Kılınç
dc.contributor.author Karabörk, Hakan
dc.contributor.author Makineci, Hasan Bilgehan
dc.date.accessioned 2021-12-13T10:32:03Z
dc.date.available 2021-12-13T10:32:03Z
dc.date.issued 2022
dc.description.abstract Unmanned aerial vehicles (UAVs), which have made a name for themselves in photogrammetry studies in recent years, provide users with integrated camera systems. Identifying interior orientation parameters, such as focal coordinates, focal length and distortions, is an essential requirement for camera systems used for photogrammetric purposes. This process, which is called camera calibration, is offered automatically by software from the library. Another important known calibration method is self-calibration. Calibrating cameras by creating 2D or 3D test areas is a troublesome and grueling option. However, it is the most commonly accepted way in terms of accuracy. In this study, images were taken in different test areas (2D and 3D) to perform the calibrations of the cameras integrated on two different UAVs, namely DJI Phantom 4 Pro and Parrot Anafi. The calibration parameters determined from the images taken were compared with the calibration parameters obtained by the self-calibration method, and block adjustment was performed with ground control points marked in the study area. In order to perform performance analysis, the root-mean-square error (RMSE) was determined from the control points. In conclusion, it was determined that the results of both the calibrations obtained with the test fields and those obtained with self-calibration were acceptable. en_US
dc.identifier.doi 10.1007/s12524-021-01454-y
dc.identifier.issn 0255-660X
dc.identifier.issn 0974-3006
dc.identifier.scopus 2-s2.0-85118618006
dc.identifier.uri https://doi.org/10.1007/s12524-021-01454-y
dc.identifier.uri https://hdl.handle.net/20.500.13091/830
dc.language.iso en en_US
dc.publisher SPRINGER en_US
dc.relation.ispartof JOURNAL OF THE INDIAN SOCIETY OF REMOTE SENSING en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Interior orientation en_US
dc.subject Non-metric camera calibration en_US
dc.subject Self-calibration en_US
dc.subject UAV en_US
dc.subject 2D en_US
dc.subject 3D camera calibration en_US
dc.title Evaluation of Test Field-Based Calibration and Self-Calibration Models of Uav Integrated Compact Cameras en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.scopusid 57326332900
gdc.author.scopusid 24921546500
gdc.author.scopusid 57191188477
gdc.bip.impulseclass C4
gdc.bip.influenceclass C5
gdc.bip.popularityclass C4
gdc.coar.access metadata only access
gdc.coar.type text::journal::journal article
gdc.description.department Fakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, Harita Mühendisliği Bölümü en_US
gdc.description.endpage 23
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q1
gdc.description.startpage 13
gdc.description.volume 50
gdc.description.wosquality Q3
gdc.identifier.openalex W3213318276
gdc.identifier.wos WOS:000715689500001
gdc.index.type WoS
gdc.index.type Scopus
gdc.oaire.diamondjournal false
gdc.oaire.impulse 8.0
gdc.oaire.influence 3.0832752E-9
gdc.oaire.isgreen false
gdc.oaire.popularity 1.0002936E-8
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 0211 other engineering and technologies
gdc.oaire.sciencefields 02 engineering and technology
gdc.oaire.sciencefields 01 natural sciences
gdc.oaire.sciencefields 0105 earth and related environmental sciences
gdc.openalex.collaboration National
gdc.openalex.fwci 2.81578725
gdc.openalex.normalizedpercentile 0.91
gdc.openalex.toppercent TOP 10%
gdc.opencitations.count 8
gdc.plumx.mendeley 7
gdc.plumx.scopuscites 10
gdc.scopus.citedcount 10
gdc.virtual.author Karabörk, Hakan
gdc.virtual.author Makineci, Hasan Bilgehan
gdc.wos.citedcount 9
relation.isAuthorOfPublication 09ba143f-9ebf-440c-b190-f92d202bf8a9
relation.isAuthorOfPublication e9b325c4-ab4f-4305-bf8d-b7f4690879db
relation.isAuthorOfPublication.latestForDiscovery 09ba143f-9ebf-440c-b190-f92d202bf8a9

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
KılınçKazar2022_Article_EvaluationOfTestField-basedCal.pdf
Size:
1.19 MB
Format:
Adobe Portable Document Format