Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/4679
Title: Grafen oksit temelli sıvı kromatografisi (HPLC) sabit fazlarının geliştirilmesi ve ilaç moleküllerinin analizlerinde kullanımı
Other Titles: Development of graphene oxide-based liquid chromatography (HPLC) stationary phases and their use in the analysis of pharmaceutical molecules
Authors: Çınar, Naci̇ye
Advisors: Topkafa, Mustafa
Keywords: Kimya Mühendisliği
Chemical Engineering
Publisher: Konya Teknik Üniversitesi
Abstract: Bu tez çalışmasında; tıp, eczacılık, kimya, elektrik-elektronik, gıda, sensör gibi birçok alanda uygulamaları bulunan grafen oksit ve indirgenmiş grafen oksitin HPLC sabit fazı olarak elde edilmesi, karakterizasyonu, ilaç etken maddesi olan parasetamol ve kafeinin ayrılması için metot parametrelerinin belirlenmesi ve geliştirilen metotların validasyonlarının yapılması amaçlanmıştır. Sabit faz olarak kullanılacak olan grafen oksit modifiye hummers metodu ile sentezlenmiş, aminopropilsilika üzerine immobilize edilmiş, elde edilen grafen oksit silisyum (GO-Si) hidrazin ile indirgenmiştir. Elde edilen grafen oksit, GO-Si ve indirgenmiş grafen oksit siliyumun (rGO-Si) karakterizasyonu UV-vis, FTIR, XRD, TEM ve SEM analizleri ile gerçekleştirilmiştir. FTIR analizleri sonunda grafen oksitin yüksek miktarda -OH, -COOH ve C-O-C fonksiyonel gruplarına sahip olduğu, GO-Si'nin amid bağıyla bağlandığı ve rGO-Si üzerinde kısmen oksijen guplarının azaldığı tespit edilmiştir. XRD, TEM ve SEM analizlerinin FTIR analizini desteklediği görülmüştür. Yüksek basınç altında boş kolonlara doldurulan GO-Si ve rGO-Si sabit fazları üzerinde parasetamol ve kafein için izokritik ve gradient şartlarda kromatografik ayırmalar gerçekleştirilmiştir. Yapılan çalışmalar sonunda GO-Si sabit fazında parasetamol ve kafein için en iyi ayırma gradient şartlarda geliştirilen Metot 9'da tespit edilmiştir. Geliştirilen Metot 9'un validasyon parametreleri; maksimum bağıl standart sapma 0,54, geri kazanım değerlerinin %98-%99 aralığında, LOD ve LOQ değerleri sırasıyla parasetamol ve kafein için 6x10-3 - 6,5x10-3 mg/L ve 2x10-2 - 2,2x10-2 mg/L olarak hesaplanmıştır. Geliştirilen metot için t testi yapılmış ve kullanılabilirliği kanıtlanmıştır. rGO-Si sabit fazı için kemometrik dizayn ile 21 farklı metot geliştirilmiş ve bunlardan en uygun metot belirlenmiştir. Uygun metot şartları; mobil faz bileşimi %81,3 metanol-%18,7 asetonitril, akış hızı 1,2 mL/dak ve sıcaklık 23°C olarak tespit edilmiştir. Geliştirilen metodun validasyon parametreleri; maksimum bağıl standart sapma 0,85, geri kazanım değerlerinin %90-%85 aralığında, LOD ve LOQ değerleri sırasıyla parasetamol ve kafein için 4,5x10-3 - 7,7x10-3 mg/L ve 1,5x10-2 - 2,6x10-2 mg/L olarak hesaplanmıştır. Geliştirilen metot için t testi yapılmış ve kullanılabilirliği kanıtlanmıştır.
In this thesis, it is aimed to obtain graphene oxide and reduced graphene oxide, which have applications in many fields such as medicine, pharmacy, chemistry, electrical-electronics, food, sensors, as HPLC stationary phase, characterization, determination of method parameters for the separation of paracetamol and caffeine, which are active ingredients of drugs, and validation of the developed methods. Graphene oxide to be used as stationary phase was synthesized by modified hummers method, immobilized on aminopropylsilica and the obtained graphene oxide silicon (GO-Si) was reduced with hydrazine. The obtained graphene oxide, GO-Si and reduced graphene oxide silicon (rGO-Si) were characterized by UV-vis, FTIR, XRD, TEM and SEM analyses. At the end of FTIR analyses, it was found that graphene oxide has a high amount of -OH, -COOH and C-O-C functional groups, GO-Si is connected by amide bonding and partially reduced oxygen groups on rGO-Si. XRD, TEM and SEM analyses supported the FTIR analysis. Chromatographic separations for paracetamol and caffeine were carried out under isocritical and gradient conditions on GO-Si and rGO-Si stationary phases filled into empty columns under high pressure. At the end of the studies, the best separation for paracetamol and caffeine in GO-Si stationary phase was determined in Method 9 developed under gradient conditions. The validation parameters of the developed Method 9 were calculated as maximum relative standard deviation 0.54, recovery values in the range of 98%-99%, LOD and LOQ values 6x10-3 - 6.5x10-3 mg/L and 2x10-2 - 2.2x10-2 mg/L for paracetamol and caffeine, respectively. A t-test was performed for the developed method and its usability was proven. For rGO-Si stationary phase, 21 different methods were developed by chemometric design and the most suitable method was determined. Suitable method conditions were determined as mobile phase composition 81.3% methanol 18.7% acetonitrile, flow rate 1.2 mL/min and temperature 23°C. The validation parameters of the developed method were calculated as maximum relative standard deviation 0.85, recovery values in the range of 90%-85%, LOD and LOQ values of 4,5x10-3 - 7,7x10-3 mg/L and 1,5x10-2 - 2,6x10-2 mg/L for paracetamol and caffeine, respectively. A t-test was performed for the developed method and its usability was proved.
URI: https://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=j_Fjwp4JS4mk97Puqti8rotQB-xOAtnzFECjzlzpQ1cHzyh_4kUz5pzdi5JXIbak
https://hdl.handle.net/20.500.13091/4679
Appears in Collections:Tez Koleksiyonu

Files in This Item:
File SizeFormat 
809024.pdf4.56 MBAdobe PDFView/Open
Show full item record



CORE Recommender

Page view(s)

406
checked on Apr 29, 2024

Download(s)

140
checked on Apr 29, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.