Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/4539
Title: Kaliks[4]aren amit ve Schiff bazi türevleri kullanilarak sulu ortamda bazi farmasötik bilesiklerin kalitatif ve kantitatif olarak algilanmasi
Other Titles: Qualitative and quantitative sensing of some pharmaceutical compounds by calix[4]arene amide and Schiff base derivatives in aqueous media
Authors: Özçelik, Egemen
Advisors: Tabakcı, Mustafa
Keywords: Kimya Mühendisliği
Chemical Engineering
Dizin:Kimyasal sensör = Chemical sensor ; Optik sensörler = Optical sensors
Publisher: Konya Teknik Üniversitesi
Abstract: Bu çalışmada, son yıllarda kullanımı artan ilaçların etken maddesi olan farmasötik bileşiklerin sulu ortamda kalitatif ve kantitatif olarak tespit edilmesi amaçlandı. Bunun için, farklı fonksiyonel gruplar içeren kaliks[4]aren Schiff bazı ve amit türevleri kullanılarak spektroskopik ve QCM sensör çalışmaları gerçekleştirildi. Rodamin B ve floresein yapıları kullanılarak sırasıyla kaliks[4]aren K-Rh ve K-Fl türevleri, 8-hidroksikinolin, 5-fenilazo-8-hidroksikinolin, benzatiyazol ve semikarbazit yapıları kullanılarak ise sırasıyla kaliks[4]aren K-8HQ, K-8HA, K-Ben ve K-SK türevleri sentezlendi ve tüm bileşiklerin yapıları 1H-NMR spektroskopisi ile doğrulandı. Bu bileşiklerin daha sonra seçilmiş bazı farmasötik bileşikler (askorbik asit (AA), difenhidramin (DIF), 4-dimetilaminoantipirin (DMAP), trimetoprim (TRI), sülfametoksazol (SUL), atenolol (ATE), naproksen (NAP), fenitoin (FEN), ibuprofen (IBU) ve parasetamol (PAR)) için sensör özellikleri öncelikle spektroskopik olarak incelendi. QCM sensör çalışmaları ise spektroskopik sensör özelliği olan bileşikler için gerçekleştirildi. K-Rh türevinin etanol-su ortamında farklı farmasötik bileşiklere karşı spektroskopik sensör özellikleri incelendiğinde AA'ya karşı florimetrik olarak seçimli ve hassas bir sensör olduğu görüldü. Burada K-Rh türevinin sensör özelliğinin ortaya çıkmasında yapı üzerinde halka açılma reaksiyonunun gerçekleşmesiyle 585 nm'de şiddetli bir emisyonun gözlenmesinin etkili olduğu şeklinde değerlendirildi. K-Rh:AA komplekleşmesinin 1:1 oranında gerçekleştiği ve sensörün LOD değerinin 2,59 µM olduğu belirlendi. K-Rh türevinin AA için QCM çalışmaları da gerçekleştirildi. Fonksiyonel grubun etkisini görmek amacıyla aldehit grubu taşıyan kaliks[4]aren K-4 türevi ile karşılaştırıldığında AA algılanmasında rodamin gruplarının etkili olduğu görüldü. Stokiyometrik oran değerlerinden algılamada K-Rh ve AA arasında 1:1 oranında etkileşim olduğu belirlendi. Bu da hem spektroskopik yöntemin hem de QCM yönteminin bu noktada birbirini doğruladığını gösterdi. K-Fl türevinin asetonitril-su ortamında farklı farmasötik bileşiklere karşı spektroskopik sensör özellikleri incelendiğinde kayda değer bir sonuç gözlenmedi. Bunun üzerine ikinci bir yöntem olarak K-Fl türevinin aynı koşullarda farklı katyonlara karşı spektroskopik sensör özellikleri incelendiğinde Cu2+ iyonuna karşı kolorimetrik olarak seçimli ve hassas bir sensör olduğu görüldü. Burada K-Fl türevinin sensör özelliğinin ortaya çıkmasında yapı üzerindeki floresein gruplarına bağlı olarak 535 nm'de şiddetli absorpsiyon maksimumu vermesinin etkili olduğu şeklinde değerlendirildi. K-Fl:Cu2+ kompleksleşmesinin 1:2 oranında gerçekleştiği ve sensörün LOD değerinin 5,3 µM olduğu belirlendi. Yöntemin devamında K-Fl:Cu2+ kompleksinin üzerine farklı farmasötik bileşikler ilave edildiğinde kolorimetrik olarak FEN için 652 nm'de yeni bir absorpsiyon maksimumunun oluştuğu görüldü. Aynı zamanda florimetrik olarak da FEN ilavesinde çözelti renginin değiştiği ve oluşan kompleksin floresein halkasını açmaya zorlayarak 518 nm'de şiddetli bir emisyon gerçekleştiği görüldü. Ayrıca K-Fl türevinin etanol-su ortamında farklı farmasötiklere karşı spektroksopik sensör özellikleri incelendiğinde ATE, NAP, FEN ve IBU için floresans spektrumunlarında değişimler gözlendi. Ancak burada ilgili farmasötik bileşiklerin bazik karakterli olmasından dolayı halkanın kompleksleşme nedeniyle değil de ortamın pH'sının değişmesinden dolayı açıldığı belirlendi. Bunun üzerine bu kez K-Fl türevinin etanol-su ortamında farklı katyonlara karşı spektroskopik sensör özellikleri incelendiğinde ise Hg2+ iyonu için floresein halkasının açılmasından dolayı 518 nm'de şiddetli bir emisyon gözlendi. K-Fl:Hg2+ kompleksleşmesinin 1:2 oranında gerçekleştiği ve sensörün LOD değerinin 0,15 µM olduğu belirlendi. K-Fl:Hg2+ kompleksinin üzerine farklı farmasötik bileşikler ilave edildiğinde ise kayda değer bir değişim gözlenmedi. K-8HA türevinin asetonitril-su ortamında farklı farmasötik bileşiklere karşı spektroskopik sensör özellikleri incelendiğinde kayda değer bir sonuç gözlenmedi. İkinci bir yöntem olarak aynı şartlarda K-8HA türevinin farklı katyonlara karşı spektroskopik sensör özellikleri incelendiğinde de kayda değer bir değişim olmadı. Bunun üzerine benzer yapıda ancak azo grubu içermeyen 8-hidroksikinolin ile fonksiyonlandırılmış K-8HQ türevinin asetonitril-su ortamında farklı farmasötik bileşiklere karşı spektroskopik sensör özellikleri incelendiğinde ise yine kayda değer bir değişim gözlenmedi. Ancak ikinci bir yöntem olarak K-8HQ türevinin aynı koşullarda farklı katyonlara karşı spektroskopik sensör özellikleri incelendiğinde Cu2+ iyonuna karşı kolorimetrik olarak seçimli ve hassas bir sensör olduğu görüldü. Burada K-8HQ türevinin sensör özelliğinin ortaya çıkmasında yapı üzerindeki 8-hidroksikinolin gruplarına bağlı olarak 490 nm'de şiddetli bir absorpsiyon maksimumu vermesinin etkili olduğu şeklinde değerlendirildi. K-8HQ:Cu2+ kompleksleşmesinin 1:1 oranında gerçekleştiği ve sensörün LOD değerinin 3 µM olduğu belirlendi. Yöntemin devamında ise K-8HQ:Cu2+ kompleksinin üzerine farklı farmasötik bileşikler ilave edildiğinde florimetrik olarak herhangi değişim gözlenmezken kolorimetrik olarak sadece DMAP için renk değişiminin gözlendiği ancak oluşan K-8HQ:DMAP kompleksinin kararlılığının zayıf olduğu görüldü. K-Ben türevinin DMSO-su ortamında farklı farmasötik bileşiklere karşı spektroskopik sensör özellikleri incelendiğinde kayda değer bir sonuç gözlenmedi. Bunun üzerine ikinci bir yöntem olarak K-Ben türevinin aynı koşullarda farklı katyonlara karşı spektroskopik sensör özellikleri incelendiğinde Zn2+ iyonuna karşı florimetrik olarak seçimli ve hassas bir sensör olduğu görüldü. Burada K-Ben türevinin sensör özelliğinin ortaya çıkmasında yapı üzerindeki benzotiyazol gruplarına bağlı olarak 480 nm'de şiddetli bir emisyon vermesinin etkili olduğu şeklinde değerlendirildi. K-Ben:Zn2+ kompleksleşmesinin 1:1 oranında gerçekleştiği ve sensörün LOD değerinin 2,6 µM olduğu belirlendi. K-Ben:Zn2+ kompleksinin üzerine farklı farmasötik bileşikler ilave edildiğinde ise DIF durumunda kompleksin bozulduğu ve 480 nm'deki emisyonun sönümlendiği görüldü. K-Ben türevinin DIF için QCM çalışmaları da gerçekleştirildi. Elde edilen frekans değişimleri incelendiğinde konsantrasyon değeri arttıkça, frekans değişiminin arttığı, ancak artış hızının giderek azaldığı görüldü. Stokiyometrik oran değerlerinden algılamada K-Ben ve DIF arasında 1:1 oranında etkileşim olduğu belirlendi. Bu da hem spektroskopik yöntemin hem de QCM yönteminin bu noktada birbirini doğruladığını gösterdi. K-SK türevi kaplı QCM sensörün farklı farmasötik bileşiklerin sulu ortamda algılama çalışmaları gerçekleştirildiğinde NAP ve IBU için en yüksek frekans değişimlerinin meydana geldiği, en düşük frekans değişiminin de AA için elde edildiği görüldü. Yapılan tüm QCM çalışmalarında kaplama kalınlığının etkisi incelendi ve kaplama kalınlığı arttıkça stokiyometrik oran değerlerinde azalma olduğu görüldü. Bunun başlıca sebebinin, yüzeyde bulunan algılayıcı madde miktarının fazla olması dolayısıyla kaplama sürecinde moleküllerin üst üste gelerek çoklu tabaka oluşturması nedeniyle algılayıcı bölgelerin kapanması olarak değerlendirildi. Her ne kadar düşük kaplama değerlerinde stokiyometrik olarak yüksek algılama gerçekleşse de algılama kapasitesi düşük oldu. QCM çalışmalarında etkileşimlerin adsorpsiyon prosesi üzerinden yürümesi nedeniyle Langmuir, Freundlich ve Scatchard izotermleri çizilerek adsorpsiyon parametreleri belirlendi.
In this study, it was aimed to qualitatively and quantitatively determine the pharmaceutical compounds, which are the active ingredients of drugs, the use of which has increased in recent years, in aqueous media. For this, spectroscopic and QCM sensor studies were performed using calix[4]arene Schiff base and amide derivatives containing different functional groups. Using the Rhodamine B and fluorescein structures, calix[4]arene K-Rh and K-Fl derivatives, 8-hydroxyquinoline, 5-phenylazo-8-hydroxyquinoline, benzathiazole and semicarbazide structures, respectively, were used as calix[4]arene K-8HQ, K-8HA, K-Ben and K-SK derivatives were synthesized, and the structures of all compounds were confirmed by 1H-NMR spectroscopy. Some of these compounds were later selected pharmaceutical compounds (ascorbic acid (AA), diphenhydramine (DIF), 4-dimethylaminoantipyrine (DMAP), trimethoprim (TRI), sulfamethoxazole (SUL), atenolol (ATE), naproxen (NAP), phenytoin (FEN), ibuprofen (IBU) and paracetamol (PAR)) were first examined spectroscopically. QCM sensor studies were carried out for compounds with spectroscopic sensor properties. When the spectroscopic sensor properties of the K-Rh derivative against different pharmaceutical compounds in ethanol-water environment were examined, it was seen that it was a fluorimetrically selective and sensitive sensor against AA. Here, it was evaluated that the observation of a severe emission at 585 nm with the ring opening reaction on the structure was effective in the emergence of the sensor feature of the K-Rh derivative. It was determined that K-Rh:AA complexation occurred at a ratio of 1:1 and the LOD value of the sensor was 2.59 µM. QCM studies for AA of the K-Rh derivative were also performed. In order to see the effect of the functional group, rhodamine groups were found to be effective in the detection of AA when compared with the calix[4]arene K-4 derivative carrying the aldehyde group. It was determined that there was a 1:1 interaction between K-Rh and AA in detection from stoichiometric ratio values. This showed that both the spectroscopic method and the QCM method confirmed each other at this point. When the spectroscopic sensor properties of the K-Fl derivative against different pharmaceutical compounds in acetonitrile-water medium were examined, no significant results were observed. Then, as a second method, when the spectroscopic sensor properties of the K-Fl derivative against different cations were examined under the same conditions, it was seen that it was a colorimetrically selective and sensitive sensor against Cu2+ ion. Here, it was evaluated that the strong absorption maximum at 535 nm, depending on the fluorescein groups on the structure, was effective in the emergence of the sensor feature of the K-Fl derivative. It was determined that K-Fl:Cu2+ complexation occurred at a ratio of 1:2 and the LOD value of the sensor was 5.3 µM. In the continuation of the method, when different pharmaceutical compounds were added to the K-F1:Cu2+ complex, it was observed that a new absorption maximum was formed for FEN colorimetrically at 652 nm. At the same time, fluorimetrically, it was observed that the color of the solution changed with the addition of FEN and a severe emission occurred at 518 nm, forcing the fluorescein ring of the formed complex to open. In addition, when the spectroscopic sensor properties of the K-Fl derivative against different pharmaceuticals in ethanol-water environment were examined, changes in the fluorescence spectra were observed for ATE, NAP, FEN and IBU. However, due to the basic character of the relevant pharmaceutical compounds, it was determined that the ring was opened not because of complexation, but because of the change in the pH of the environment. Then, when the spectroscopic sensor properties of the K-Fl derivative against different cations in the ethanol-water environment were examined, a severe emission was observed at 518 nm due to the opening of the fluorescein ring for the Hg2+ ion. It was determined that K-Fl:Hg2+ complexation occurred at a ratio of 1:2 and the LOD value of the sensor was 0.15 µM. No significant change was observed when different pharmaceutical compounds were added to the K-F1:Hg2+ complex. When the spectroscopic sensor properties of the K-8HA derivative against different pharmaceutical compounds in acetonitrile-water medium were examined, no significant results were observed. As a second method, when the spectroscopic sensor properties of the K-8HA derivative against different cations were examined under the same conditions, there was no significant change. On top of that, when the spectroscopic sensor properties of the 8-hydroxyquinoline-functionalized K-8HQ derivative, which has a similar structure but does not contain azo group, against different pharmaceutical compounds in acetonitrile-water medium, no significant change was observed. However, as a second method, when the spectroscopic sensor properties of the K-8HQ derivative against different cations were examined under the same conditions, it was seen that it was a colorimetrically selective and sensitive sensor against Cu2+ ion. Here, it was evaluated that the K-8HQ derivative gave a strong absorption maximum at 490 nm depending on the 8-hydroxyquinoline groups on the structure. It was determined that K-8HQ:Cu2+ complexation occurred at a ratio of 1:1 of the and the LOD value of the sensor was 3 µM. In the continuation of the method, when different pharmaceutical compounds were added to the K-8HQ:Cu2+ complex, no fluorimetric change was observed, while colorimetrically only color change was observed for DMAP, but the stability of the formed K-8HQ:DMAP complex was weak. When the spectroscopic sensor properties of the K-Ben derivative against different pharmaceutical compounds in DMSO-water medium were examined, no significant results were observed. Then, as a second method, when the spectroscopic sensor properties of the K-Ben derivative against different cations were examined under the same conditions, it was seen that it was a fluorimetrically selective and sensitive sensor against Zn2+ ion. Here, it was evaluated that the K-Ben derivative's intense emission at 480 nm, depending on the benzothiazole groups on the structure, was effective in the emergence of the sensor feature. It was determined that K-Ben:Zn2+ complexation occurred at a ratio of 1:1 and the LOD value of the sensor was 2.6 µM. When different pharmaceutical compounds were added to the K-Ben:Zn2+ complex, it was observed that the complex was disrupted in the case of DIF and the emission at 480 nm was quenched. QCM studies for DIF of the K-Ben derivative were also performed. When the frequency changes obtained were examined, it was observed that as the concentration value increased, the frequency change increased, but the rate of increase gradually decreased. It was determined that there was a 1:1 interaction between K-Ben and DIF in detection from stoichiometric ratio values. This showed that both the spectroscopic method and the QCM method confirmed each other at this point. When the detection studies of different pharmaceutical compounds in aqueous medium of the K-SK derivative coated QCM sensor were performed, it was observed that the highest frequency changes occurred for NAP and IBU, and the lowest frequency change was obtained for AA. In all QCM studies, the effect of the coating thickness was examined and it was observed that the stoichiometric ratio values decreased as the coating thickness increased. The main reason for this was considered to be the closure of the sensing areas due to the large amount of sensing substance on the surface and the formation of multiple layers by overlapping the molecules during the coating process. Although stoichiometric high detection was achieved at low coating values, the detection capacity was low. In QCM studies, the adsorption parameters were determined by drawing the Langmuir, Freundlich and Scatchard isotherms, since the interactions are based on the adsorption process.
URI: https://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=r4I1HnmXxFQovUpyAyUmxB0-thvt8xLLgDdtwzZJno_2_OWiMHNbr5deGXxtQycF
https://hdl.handle.net/20.500.13091/4539
Appears in Collections:Tez Koleksiyonu

Files in This Item:
File SizeFormat 
780116.pdf7.66 MBAdobe PDFView/Open
Show full item record



CORE Recommender

Page view(s)

74
checked on Apr 22, 2024

Download(s)

6
checked on Apr 22, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.