Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/3584
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorAkdemir, Bayram-
dc.contributor.authorAbafogı, Motuma Muktar-
dc.date.accessioned2023-02-22T18:13:17Z-
dc.date.available2023-02-22T18:13:17Z-
dc.date.issued2022-
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=sELqxhTlFGAjsbjOuuiyCJooBjzyq2Y719WigUIlBYml6h2Jx90bzIoAf9yK9Wfx-
dc.identifier.urihttps://hdl.handle.net/20.500.13091/3584-
dc.description.abstractDar bantlı güç hattı haberleşmesi, konut ortamlarındaki potansiyel uygulamalarla birlikte çalışmanın önemli bir odak noktası olmaktadır. Asansör kumanda panosundan kabine giden esnek AC güç hattı kabloları üzerinden veri aktarımı bu tezin konusudur. Önceki araştırmalarda, bir asansör sisteminin PLC kanal tepkisini ve gürültüsünü karakterize etmek için hiçbir zaman ciddi bir girişimde bulunulmamıştır. Bir asansör sisteminin güç hattı kanal gürültüsü, bir karma alan osiloskopu kullanılarak ölçülmüştür. Kanal yanıtı ise bir vektör ağ analizörü kullanılarak elde edilmektedir. Bu ölçüm cihazları, bir asansör sisteminin AC güç hatlarına kuplaj cihazları vasıtasıyla bağlanmaktadır. Bir asansör sisteminin güç hattı kanal gürültüsü ve yanıtı, bir vektör ağ analizörü, karma alan osiloskopu ve bağlantı cihazları kullanılarak ölçülmüştür. 9 kHz - 500 kHz frekans aralığı için asansörün boş ve hareketli durumlarına karşılık gelen kanal transfer fonksiyonları alınmıştır. Ortalama PLC kanal frekans yanıtı için matematiksel bir model sunulmuştur. Asansör hız kontrolü için kullanılan invertör birincil gürültü kaynağıdır. Asansör boşta modundan hareket moduna geçerken, kanal 281 kHz'den düşük frekanslar için dikkate değer farklılıklar gösterirken, 281 kHz - 500 kHz frekans aralığında genellikle sabit kalmıştır. Bu tezde, bir dikgen frekans bölmeli çoğullama alıcı-vericisini modellemek için Reed Solomon, evrişimli kodlar ve hatalı bitleri dağıtmak için serpiştirme kullanılmıştır. Kanal yanıtı ve gürültü için elde edilen ölçüm verileri, alıcı-verici sistemini modellemek için kullanılmıştır. Simülasyon deneyleri, harmonik gürültü bileşenleriyle örtüşmeyen alt taşıyıcı frekanslarını metodik olarak seçerek 4 dB'den daha büyük bir sinyal-gürültü oranı için başarılı bir veri kurtarma göstermiştir.en_US
dc.description.abstractNarrowband power line communication has been a significant focus of study, with potential applications in residential settings. The data transfer across flexible AC power line cables extending from the elevator control panel to the cabin is the subject of this thesis. In prior research, there has never been a serious attempt to characterize the PLC channel response and noise of an elevator system. An elevator system's power line channel noise is measured using a mixed domain oscilloscope. The channel response, on the other hand, is measured using a vector network analyzer. These measurement devices are connected to the AC power lines of an elevator system via coupling devices. For the 9 kHz - 500 kHz frequency range, channel transfer functions corresponding to the elevator's idle and moving states are acquired. For the average PLC channel frequency response, a mathematical model is presented. The inverter used for elevator speed control is the primary noise source. As the elevator moves from idle to moving mode, the channel shows noticeable variances for frequencies less than 281 kHz while generally constant within the 281 kHz-500 kHz frequency range. This thesis has utilized Reed Solomon, convolutional codes, and interleaving to distribute erroneous bits to model an orthogonal frequency division multiplexing transceiver. Acquired measurement data for the channel response and noise is used to model the transceiver system. Simulation experiments have shown successful data recovery for a signal-to-noise ratio larger than 4 dB by methodically selecting subcarrier frequencies that do not coincide with the harmonic noise components.en_US
dc.language.isotren_US
dc.publisherKonya Teknik Üniversitesien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectElektrik ve Elektronik Mühendisliğien_US
dc.subjectElectrical and Electronics Engineeringen_US
dc.subjectAsansören_US
dc.subjectElevatoren_US
dc.subjectGürültüen_US
dc.subjectNoiseen_US
dc.titleAsansör kabinlerinde esnek kablolar üstünden güç hattı haberleşmesien_US
dc.title.alternativePower line communication over flexible cables for elevator cabinsen_US
dc.typeDoctoral Thesisen_US
dc.departmentEnstitüler, Lisansüstü Eğitim Enstitüsü, Elektrik ve Elektronik Mühendisliği Ana Bilim Dalıen_US
dc.identifier.startpage1en_US
dc.identifier.endpage84en_US
dc.institutionauthorAbafogı, Motuma Muktar-
dc.relation.publicationcategoryTezen_US
dc.identifier.yoktezid749867en_US
item.grantfulltextopen-
item.openairetypeDoctoral Thesis-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1tr-
item.cerifentitytypePublications-
Appears in Collections:Tez Koleksiyonu
Files in This Item:
File SizeFormat 
749867 (1).pdf3.24 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

104
checked on Apr 29, 2024

Download(s)

36
checked on Apr 29, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.