Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/2511
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorKoçer, Hasan Erdinç-
dc.contributor.authorYıldırım, Sema-
dc.date.accessioned2022-07-05T20:36:03Z-
dc.date.available2022-07-05T20:36:03Z-
dc.date.issued2021-
dc.identifier.urihttps://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=CG8WvdvvxJP04Unr7Yecfw_aDtSbbCWY2WA3RTeaQoKtwJpcZI0EQnJtcmR7PFww-
dc.identifier.urihttps://hdl.handle.net/20.500.13091/2511-
dc.description.abstractElektroensefalografi (EEG), beyin tarafından üretilen elektriksel aktivitelerin, invaziv (acısız) olmayan bir şekilde elde edilmesine ve görüntülenmesine izin veren bir tekniktir. Bu teknik ile beyin sinyallerini değerlendirmek, nörolojik bozuklukları ve sinir sistemindeki belirli durumları tespit etmek mümkündür. Öte yandan EEG ile, beyin dışından kaynaklanan elektrot, yutkunma, öksürme, göz ve kalp hareketi gibi istenmeyen sinyallerde (gürültü) kayıt altına alınabilmektedir. Çok kanallı EEG'lerdeki büyük miktardaki bilginin incelenebilmesi ve yorumlanabilmesi uzun zaman almaktadır. Bununla birlikte gürültü ile kirlenmiş EEG sinyallerinin inceleme ve yorumlanma süresi dahada artmakta ve olası epileptiform aktivitelerin gözden kaçırılmasına neden olmaktadır. Bu nedenle EEG sinyallerindeki gürültülerin giderilmesini sağlayan otomatik sistemlere ihtiyaç duyulmaktadır. EEG sinyallerinde gözlemlenen gürültülerden biri Elektrokardiyogram (EKG) sinyalidir. EKG sinyalleri düzenli bir desene sahip sinyaller olup, morfolojileri bakımından diken ve keskin dalgalarla karıştırılabilir. EEG sinyallerinde düzenli aralıklarla gözlemlenebilen diken ve keskin dalgalar, her zaman epileptiform aktivite olarak değerlendirilemez. Bu nedenle, bu tez çalışmasında EEG sinyallerindeki EKG gürültülerinin, yüksek doğrulukla giderilmesi hedeflenmiştir. Bunun için EKG gürültü gideriminde Sıfır Faz Filtreleme (SFF, Zero Phase Filtering-ZPF) ile Normalleştirilmiş En Küçük Ortalama Kareler (NEKOK, Normalized Least Mean Square Filtering-NLMS) filtreleme metotları kullanılmıştır. EKG gürültüsünün EEG sinyalindeki etkileri, bazı epileptiform aktiviteler kullanılarak incelenmiştir. İncelenen epileptiform aktivitelerden ilki, Faz Karşılaşmaları (FK)'dır. İki kutuplu montajlarda gözlemlenebilen FK, maksimum voltajın yerinin göstergesi olup, özellikle fokal epilepsilerin lokalizasyonunun tespitinde oldukça önemlidir. Çalışmada incelenen diğer epileptiform aktivite ise YD'lardır. İktal dönemdeki EEG sinyalleri genellikle ritmik olarak gözlemlendiğinden, böylesi durumlarda YD'lar önemli bir işaret haline gelmektedir. Bu tez çalışmasında ele alınan FK ve YD tespiti için sırasıyla pik bulma (iPeak) ve MinPeakProminence (MPP) metotları kullanılmıştır. Çalışmadaki tüm metotların performans değerlendirmesinde, sınıflandırıcı metrikleri (karışıklık matrisi, doğruluk vb.) kullanılmıştır. Tez çalışması temelde iki bölümden oluşmaktadır. Birinci bölüm, gürültü giderimi yapılmayan ham EEG sinyalindeki FK'nın ve YD'ların tespit edilmesinden, ikinci bölüm ise filtreleme yapıldıktan sonra EKG gürültüsü giderilmiş EEG sinyalindeki FK'nın ve YD'ların tespit edilmesinden oluşmaktadır. Uygulanan metotların performanslarının değerlendirilmesinde, Selçuk Üniversitesi Tıp Fakültesi Hastanesi Nöroloji Bölümü'nden retrospektif olarak temin edilen EEG veri seti (SÜH) ile halka açık olan Boston Çocuk Hastanesinden alınan veri seti (CHB-MIT) ve Bonn Üniversitesi Epileptoloji Anabilim Dalı'ndan alınan veri setleri (BONN) kullanılmıştır. Bu tez çalışmasında, EKG gürültülerinin EEG sinyalinde bulunan FK ve YD'lar üzerindeki etkilerinin incelenmesi için yapılan deneylerde, SÜH veri setindeki ham EEG sinyallerindeki FK ve YD'ların tespitinde elde edilen doğruluk oranları sırasıyla, %83.1 ve %95.5 olarak tespit edilmiştir. EKG gürültüsünün gideriminden sonra elde edilen doğruluk oranları ise SFF sonucunda FK'nın tespiti için %88.97, YD tespiti için %95.3; NEKOK filtreleme sonucunda FK'nın tespiti için %86.29, YD tespiti için %95.2 olarak bulunmuştur. Elde edilen doğruluk oranları incelendiğinde, FK'nın tespitinde EKG gürültü gideriminin başarıyı arttırdığı, YD tespitinde ise başarı üzerinde büyük bir etki yaratmadığı gözlenmiştir. Bilindiği üzere EKG sinyalleri yüksek genliğe sahip sinyallerdir ve bu sebeple FK olabilecek sinyalleri gizleyebilmektedir. Çalışmada FK tespitindeki başarının artmasının sebebi, yüksek genlikli olan EKG gürültülerinin giderilmesi ile birlikte FK'nın ortaya çıkmasıdır. Öte yandan YD'lar ise düşük genliğe ve frekansa sahip dalgalardır. Bu nedenle yüksek genliğe sahip olan EKG gürültüsünün giderilmesi sonrasında YD tespitindeki başarıda belirgin bir farklılık izlenmemiştir. Sonuç olarak yapılan bu tez çalışması ile EKG gürültü giderimi ile EEG sinyalindeki FK'nın tespitine katkı sağlanmıştır. İleride yapılacak bir çalışma ile EKG gürültüsünün diken ve keskin dalgaların tespitine olan etkileri de araştırılabilir.en_US
dc.description.abstractElectroencephalography (EEG) is a technique that allows non-invasive acquisition and visualization of electrical activities produced by the brain. With this technique, it is possible to evaluate brain signals, detect neurological disorders and certain conditions in the nervous system. On the other hand, EEG signals (EEGs) may also contain unwanted signals (artifacts) originating from outside the brain. It takes a long time to analyze and interpret the large amount of information in long-term EEGs. However, the duration of examination and interpretation of artifact-contaminated EEGs increases further, causing possible epileptiform activities to be overlooked. For this reason, automatic systems are needed to remove artifacts in EEGs. One of the artifacts observed in EEG signals is the Electrocardiogram (ECG) signal. ECG signals have a regular pattern and can be confused with spikes and sharp waves in terms of their morphology. Spikes and sharp waves that can be observed at regular intervals in EEGs cannot always be considered as epileptiform activity. Therefore, in this thesis, it is aimed to eliminate ECG artifacts in EEGs with high accuracy. For this, Zero Phase Filtering (ZPF) and Normalized Least Mean Square Filtering (NLMS) methods were used for ECG artifacts removal. The effects of ECG artifacts on the EEGs were investigated using some epileptiform activities. The first of the epileptiform activities examined is Phase Reversal (PR). PR, which can be observed in bipolar montages, is an indicator of the location of the maximum voltage and is very important especially in the determination of the localization of focal epilepsies. The other epileptiform activity examined in the study is Slow Wave (SW). Since EEGs in the ictal period are usually observed rhythmically, SW becomes an important sign in such cases. Peak detection (iPeak) and MinPeakProminence (MPP) methods were used for the detection of PR and SW, which are discussed in this thesis, respectively. In the performance evaluation of all methods in the study, classifier metrics (such as confusion matrix, accuracy) were used. The thesis basically consists of two parts. The first part consists of detecting the PR and SW in the raw EEGs without artifact removal, and the second part consists of detecting the PR and SW in the EEGs obtained after removing the ECG artifact with filtering. In the evaluation of the performances of the applied methods, the EEG dataset obtained retrospectively from the Neurology Department of the Selcuk University Medical Faculty Hospital (SUH), the dataset from the Boston Children's Hospital (CHB-MIT) and the dataset from the Bonn University Epileptology Department (BONN), which is open to the public, were used. In this thesis study, in the experiments conducted to examine the effects of ECG artifacts on the PR and SW in the EEGs, the accuracy rates obtained in the detection of the PR and SW in the raw EEGs in the SÜH data set were determined as 83.1% and 95.5%, respectively. The accuracy rates obtained after the removal of the ECG artifacts were 88.97% for the detection of PR and 95.3% for the detection of SW as a result of ZPF; As a result of NLMS filtering, it was found to be 86.29% for the detection of PR and 95.2% for the detection of SW. When the obtained accuracy rates were examined, it was observed that ECG artifact removal increased the success in the detection of PR, but did not have a great effect on the success in the detection of SW. As it is known, ECG signals are signals with high amplitude and therefore they can hide signals that may be PR. The reason for the increase in the success in detecting PR in the study is the emergence of PR with the elimination of high amplitude ECG artifacts. On the other hand, SW is waves with low amplitude and frequency. Therefore, after removing the high amplitude ECG artifact, no significant difference was observed in the success of SW detection. As a result, this thesis study contributed to the detection of PR in the EEGs with ECG artifact removal. In a future study, the effects of ECG artifacts on the detection of spikes and sharp waves can be investigated.en_US]
dc.language.isotren_US
dc.publisherKonya Teknik Üniversitesien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBilgisayar Mühendisliği Bilimleri-Bilgisayar ve Kontrol = Computer Engineering and Computer Science and Controlen_US
dc.titleEEG sinyallerindeki ekg gürültüsünün faz karşılaşması ve yavaş dalganın tespitine etkisinin incelenmesien_US
dc.title.alternativeThe investigation of the effect of phase reversal and slow wave detection of ecg artifact in EEG signalsen_US
dc.typeDoctoral Thesisen_US
dc.departmentEnstitüler, Lisansüstü Eğitim Enstitüsü, Bilgisayar Mühendisliği Ana Bilim Dalıen_US
dc.identifier.startpage1en_US
dc.identifier.endpage117en_US
dc.institutionauthorYıldırım, Sema-
dc.relation.publicationcategoryTezen_US
dc.identifier.yoktezid723447en_US
item.cerifentitytypePublications-
item.grantfulltextopen-
item.languageiso639-1tr-
item.openairetypeDoctoral Thesis-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
Appears in Collections:Tez Koleksiyonu
Files in This Item:
File SizeFormat 
723447.pdf5.36 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

1,040
checked on Oct 14, 2024

Download(s)

232
checked on Oct 14, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.