Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.13091/2266
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Anadol, Mehmet Ali | - |
dc.contributor.author | Karaçam, Burak | - |
dc.date.accessioned | 2022-05-21T21:04:03Z | - |
dc.date.available | 2022-05-21T21:04:03Z | - |
dc.date.issued | 2022 | - |
dc.identifier.uri | https://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=5XiSE4yCP_gmnukpMEp65SBLY2JHCcF7Xij_iwi06-ZIvqnpFfyk11oMh-ME1p8F | - |
dc.identifier.uri | https://hdl.handle.net/20.500.13091/2266 | - |
dc.description.abstract | Bu tez çalışması, kar yağışı ve buzlanmanın farklı panel, eğim açısı ve inverter teknolojisine sahip şebeke bağlantılı fotovoltaik tesislerin performansına etkilerini belirlemek ve değerlendirmek için gerçekleştirilmiştir. Performans analizleri, aynı tesis alanı içinde kurulmuş şebeke bağlantılı hibrid inverter ve mikroinverter sistemlerine ait gerçek çalışma koşullarındaki işletme verileri ve meteorolojiden temin edilen atmosferik değişkenler kullanılarak gerçekleştirilmiştir. Şebeke bağlantılı hibrid inverter sistemi, taşıyıcı sistem üzerinde 30° sabit eğim açısı ile güney yönünde ve yatay doğrultuda yerleştirilmiş olan 36 adet monokristal yapılı panelden oluşmaktadır. Şebeke bağlantılı mikro inverter sistemi ise çift panel girişli dokuz adet mikro inverter ile 0°, 10°, 20°, 30°, 40° ve 50°'lik altı farklı sabit eğim açısıyla güney yönünde ve yatay doğrultuda taşıyıcı sistem üzerinde yerleştirilmiş 18 adet polikristal yapılı panelden oluşmaktadır. Bu fotovoltaik tesisler, Konya Teknik Üniversitesi kampüs alanı içinde Teknik Bilimler Meslek Yüksek Okuluna ait açık tesis alanına kurulmuştur. Hibrid ve mikroinverter sistemleri için elde edilen performans sonuçları, dizi verim, nihai verim, referans verim, sistem kaybı, dizi yakalama kaybı, inverter verimliliği, performans oranı, sistem verimliliği ve kapasite faktörü olarak bilinen performans değişkenleri üzerinden literatürdeki önceki çalışmalarda elde edilmiş sonuçlarla karşılaştırılmıştır. Sonuçlar, panel yüzeylerinde biriken kar ve buzlanmanın her iki inverter sisteminde de kayıplara neden olduğunu ve birbirine seri bağlı birçok panelden oluşan hibrid inverter sistemini mikroinverter sistemine nazaran daha çok etkilediğini göstermektedir. | en_US |
dc.description.abstract | This thesis study was carried out to determine and evaluate the effects of snowfall and icing on the performance of grid-connected photovoltaic plants with different panels, inclination angles and inverter technology. Performance analyzes were carried out using atmospheric variables obtained from meteorology station and operational data under real operating conditions of grid-connected hybrid inverter and microinverter systems installed in the same facility area. The grid-connected hybrid inverter system consists of 36 monocrystalline panels placed on the carrier system with a fixed tilt angle of 30° in the south direction and horizontal orientation. The grid-connected microinverter system consists of nine micro-inverters with double panel inputs and 18 polycrystalline modules which are placed on the carrier system with six different fixed tilt angles of 0°, 10°, 20°, 30°, 40° and 50° in the south direction and horizontal orientation. These photovoltaic facilities were established in the open facility area of the Vocational School of Technical Sciences within the campus area of Konya Technical University. The performance results obtained for hybrid and microinverter systems were compared with the results obtained in previous studies in the literature performance variables known as string efficiency, final efficiency, reference efficiency, system loss, string capture loss, inverter efficiency, performance ratio, system efficiency and capacity factor. The results show that snow and icing accumulated on the panel surfaces cause losses in both inverter systems and affect the hybrid inverter system, which consists of many panels connected in series, more than the microinverter system. | en_US |
dc.language.iso | tr | en_US |
dc.publisher | Konya Teknik Üniversitesi | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Elektrik ve Elektronik Mühendisliği | en_US |
dc.subject | Electrical and Electronics Engineering | en_US |
dc.subject | Enerji | en_US |
dc.subject | Energy | en_US |
dc.title | Kar yağışı ve buzlanmanın şebeke bağlantılı dize ve mikro inverterlerin enerji üretimine etkisinin araştırılması | en_US |
dc.title.alternative | Investigation of the effect of snowfall and ice on energy generation of grid connected string and micro inverters | en_US |
dc.type | Master Thesis | en_US |
dc.department | Enstitüler, Lisansüstü Eğitim Enstitüsü, Elektrik-Elektronik Mühendisliği Ana Bilim Dalı | en_US |
dc.identifier.startpage | 1 | en_US |
dc.identifier.endpage | 131 | en_US |
dc.institutionauthor | Karaçam, Burak | - |
dc.relation.publicationcategory | Tez | en_US |
dc.identifier.yoktezid | 715610 | en_US |
item.languageiso639-1 | tr | - |
item.cerifentitytype | Publications | - |
item.fulltext | With Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.grantfulltext | open | - |
item.openairetype | Master Thesis | - |
Appears in Collections: | Tez Koleksiyonu |
Files in This Item:
File | Size | Format | |
---|---|---|---|
715610.pdf | 11.27 MB | Adobe PDF | View/Open |
CORE Recommender
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.