Fuzzy-Based Modeling and Speed Optimization of a Centrifugal Blood Pump Using a Modified and Constrained Bees Algorithm

dc.contributor.author İncebay, Ömer
dc.contributor.author Önder, Ahmet
dc.contributor.author Arif, Şen, Muhammed
dc.contributor.author Yapıcı, Rafet
dc.contributor.author Kalyoncu, Mete
dc.date.accessioned 2022-10-08T20:48:05Z
dc.date.available 2022-10-08T20:48:05Z
dc.date.issued 2022
dc.description.abstract Background and objective: Side effects that may occur when using blood pumps for treatment of patients are the main limitations on pump rotational speed determination. Efforts are being made to reduce side effects in both design and usage procedures. In determining the pump speed for treatment, decreasing the pressure on the main artery and preserving the valve functions are taken into consideration. In addition to these, the parameters considered for design which include pump efficiency and mechanical effects on blood cells, should also be taken into consideration. In this study, the aim is to obtain the optimum pump speed for the maximum hydraulic efficiency and minimum wall shear stresses that occur inside the pump. Methods: Blood pump modeling based on fuzzy logic is created on the hydraulic performance data of a centrifugal blood pump, whose design, CFD analysis, manufacture and experimental testing have been performed previously. Using this fuzzy logic model, the optimum pump speeds were determined using the Bees Algorithm, an intuitive optimization algorithm, in the operating range 1-7 L/min fluid flow rate. In the optimization process, the aim is to achieve minimum shear stress with maximal efficiency. Intravascular pressure limits (90-160 mm-Hg) were set as pressure constraints. Results: The optimum operating point is obtained as a 3350 rpm pump speed and a 4.35 L/min flow rate. At this operating point, CFD simulation is performed, and maximum wall shear stress was found to be 1458 Pa and its efficiency as 34.2%. Conclusions: In addition to the parameters commonly used in the pump speed optimization of blood pumps, the use of wall shear stresses and pump efficiency can provide certain improvements. © 2022 en_US
dc.description.sponsorship Submission Declaration: This is original research that has not been published previously nor is it being considered elsewhere, Funding Declaration: This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors en_US
dc.identifier.doi 10.1016/j.cmpb.2022.106867
dc.identifier.issn 0169-2607
dc.identifier.scopus 2-s2.0-85130961070
dc.identifier.uri https://doi.org/10.1016/j.cmpb.2022.106867
dc.identifier.uri https://hdl.handle.net/20.500.13091/2900
dc.language.iso en en_US
dc.publisher Elsevier Ireland Ltd en_US
dc.relation.ispartof Computer Methods and Programs in Biomedicine en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Bees algorithm en_US
dc.subject Blood pump en_US
dc.subject Fuzzy logic en_US
dc.subject Modeling en_US
dc.subject Optimization en_US
dc.subject Blood en_US
dc.subject Computational fluid dynamics en_US
dc.subject Computer circuits en_US
dc.subject Constrained optimization en_US
dc.subject Efficiency en_US
dc.subject Flow of fluids en_US
dc.subject Patient treatment en_US
dc.subject Pumps en_US
dc.subject Shear stress en_US
dc.subject Speed en_US
dc.subject Bee Algorithm en_US
dc.subject Blood pump en_US
dc.subject Centrifugal blood pump en_US
dc.subject Fuzzy-Logic en_US
dc.subject Modeling en_US
dc.subject Optimisations en_US
dc.subject Pump speed en_US
dc.subject Speed optimization en_US
dc.subject Wall shear stress en_US
dc.subject Wall-shear stress en_US
dc.subject Fuzzy logic en_US
dc.subject Article en_US
dc.subject blood pressure en_US
dc.subject controlled study en_US
dc.subject flow rate en_US
dc.subject fluid flow en_US
dc.subject fuzzy logic en_US
dc.subject hydrodynamics en_US
dc.subject learning algorithm en_US
dc.subject process optimization en_US
dc.subject processing speed en_US
dc.subject productivity en_US
dc.subject shear rate en_US
dc.subject shear stress en_US
dc.subject algorithm en_US
dc.subject computer simulation en_US
dc.subject equipment design en_US
dc.subject heart assist device en_US
dc.subject human en_US
dc.subject mechanical stress en_US
dc.subject prosthesis design en_US
dc.subject Algorithms en_US
dc.subject Computer Simulation en_US
dc.subject Equipment Design en_US
dc.subject Heart-Assist Devices en_US
dc.subject Humans en_US
dc.subject Prosthesis Design en_US
dc.subject Stress, Mechanical en_US
dc.title Fuzzy-Based Modeling and Speed Optimization of a Centrifugal Blood Pump Using a Modified and Constrained Bees Algorithm en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.institutional İncebay, Ömer
gdc.author.institutional Önder, Ahmet
gdc.author.institutional Arif, Şen, Muhammed
gdc.author.institutional Yapıcı, Rafet
gdc.author.institutional Kalyoncu, Mete
gdc.author.scopusid 57224570636
gdc.author.scopusid 57222167697
gdc.author.scopusid 57189386731
gdc.author.scopusid 16044036400
gdc.author.scopusid 55970457800
gdc.bip.impulseclass C4
gdc.bip.influenceclass C5
gdc.bip.popularityclass C4
gdc.coar.access metadata only access
gdc.coar.type text::journal::journal article
gdc.description.department Fakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, Makine Mühendisliği Bölümü en_US
gdc.description.department Meslek Yüksekokulları, Teknik Bilimler Meslek Yüksekokulu, Makine ve Metal Teknolojileri Bölümü en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q1
gdc.description.startpage 106867
gdc.description.volume 221 en_US
gdc.description.wosquality Q1
gdc.identifier.openalex W4229460029
gdc.identifier.pmid 35597207
gdc.identifier.wos WOS:000856847800006
gdc.index.type WoS
gdc.index.type Scopus
gdc.index.type PubMed
gdc.oaire.diamondjournal false
gdc.oaire.impulse 8.0
gdc.oaire.influence 2.9308334E-9
gdc.oaire.isgreen false
gdc.oaire.keywords Humans
gdc.oaire.keywords Computer Simulation
gdc.oaire.keywords Equipment Design
gdc.oaire.keywords Heart-Assist Devices
gdc.oaire.keywords Stress, Mechanical
gdc.oaire.keywords Prosthesis Design
gdc.oaire.keywords Algorithms
gdc.oaire.popularity 7.959902E-9
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 03 medical and health sciences
gdc.oaire.sciencefields 0302 clinical medicine
gdc.oaire.sciencefields 0206 medical engineering
gdc.oaire.sciencefields 02 engineering and technology
gdc.openalex.collaboration National
gdc.openalex.fwci 0.99897633
gdc.openalex.normalizedpercentile 0.67
gdc.opencitations.count 7
gdc.plumx.crossrefcites 8
gdc.plumx.mendeley 9
gdc.plumx.pubmedcites 2
gdc.plumx.scopuscites 7
gdc.scopus.citedcount 7
gdc.virtual.author Kalyoncu, Mete
gdc.virtual.author Yapıcı, Rafet
gdc.virtual.author İncebay, Ömer
gdc.virtual.author Önder, Ahmet
gdc.wos.citedcount 6
relation.isAuthorOfPublication acb2cb0c-a602-4476-9440-a475cdc73d43
relation.isAuthorOfPublication e2e5730a-9fdf-40e4-9644-225b3fbdd8fc
relation.isAuthorOfPublication 700f7e37-116f-466d-9c1b-aa8ae97b27ce
relation.isAuthorOfPublication dd6e2506-d781-4976-9df6-9bc627e72ec3
relation.isAuthorOfPublication.latestForDiscovery acb2cb0c-a602-4476-9440-a475cdc73d43

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
1-s2.0-S0169260722002498-main.pdf
Size:
3.02 MB
Format:
Adobe Portable Document Format