Small Motion Detection and Non-Contact Vital Signs Monitoring With Continuous Wave Doppler Radars

dc.contributor.author Şeflek, İbrahim
dc.contributor.author Acar, Yunus Emre
dc.contributor.author Yaldız, Ercan
dc.date.accessioned 2021-12-13T10:38:39Z
dc.date.available 2021-12-13T10:38:39Z
dc.date.issued 2020
dc.description.abstract Radars have become devices that one can come across in any environment at any moment. This means that they enter to all areas of life and even in the field of medicine and will be used more intensively in the future. Especially, the attention has been drawn to that they are suitable for the non contact vital signs monitoring. In this study, two radar structures operating at 24 GHz (Radar 1) and 2.4 GHz (Radar 2) frequencies are used. Radar 1 structure is created on a printed circuit board (PCB), whereas Radar 2 is obtained by combining discrete components. The 8.5 mm movement performed with the aid of a test mechanism is detected by two radars with percentage errors (PEs) of 2.58% and 6.23%, respectively. For the 0.25 Hz vibration frequency, the error is the same for both radars and is 2.4 %. In measurements taken from a healthy human subject, Radar 1 finds a respiration rate with 1.85 % of PE and heart beat rate with 6.17 % of PE. In Radar 2, these values are 2.35 % and 8.24 % respectively. From the measurement results, it is seen that the resolution of Radar 1 is better than that of Radar 2. The results also indicate that small motion detection and vital signs monitoring are carried out successfully. en_US
dc.identifier.doi 10.5755/j01.eic.26.3.25810
dc.identifier.issn 1392-1215
dc.identifier.scopus 2-s2.0-85090775295
dc.identifier.uri https://doi.org/10.5755/j01.eic.26.3.25810
dc.identifier.uri https://hdl.handle.net/20.500.13091/1262
dc.language.iso en en_US
dc.publisher KAUNAS UNIV TECHNOLOGY en_US
dc.relation.ispartof ELEKTRONIKA IR ELEKTROTECHNIKA en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Displacement measurement en_US
dc.subject Doppler radar en_US
dc.subject Non-contact measurement en_US
dc.subject Vital signs monitoring en_US
dc.title Small Motion Detection and Non-Contact Vital Signs Monitoring With Continuous Wave Doppler Radars en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id SEFLEK, IBRAHIM/0000-0002-6782-9513
gdc.coar.access metadata only access
gdc.coar.type text::journal::journal article
gdc.description.department Fakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, Elektrik-Elektronik Mühendisliği Bölümü en_US
gdc.description.endpage 60 en_US
gdc.description.issue 3 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality Q3
gdc.description.startpage 54 en_US
gdc.description.volume 26 en_US
gdc.description.wosquality Q4
gdc.identifier.wos WOS:000545672000007
gdc.index.type WoS
gdc.index.type Scopus
gdc.opencitations.count 0
gdc.scopus.citedcount 13
gdc.virtual.author Şeflek, İbrahim
gdc.virtual.author Yaldız, Ercan
gdc.wos.citedcount 10
relation.isAuthorOfPublication 68a12290-4e2c-4cda-9cfd-6bd6e48c2c25
relation.isAuthorOfPublication 262dc2df-528d-4176-ace8-9e09ef139269
relation.isAuthorOfPublication.latestForDiscovery 68a12290-4e2c-4cda-9cfd-6bd6e48c2c25

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
25810-Article Text-87814-1-10-20200627.pdf
Size:
1.84 MB
Format:
Adobe Portable Document Format