Static Push Over Analysis of a 5 Storey Steel Building

dc.contributor.author Köken, Ali
dc.contributor.author Özbay, Esat
dc.date.accessioned 2024-08-27T10:32:22Z
dc.date.available 2024-08-27T10:32:22Z
dc.date.issued 2020
dc.description.abstract The use of steel structures has been increasing rapidly in recent years. This is due to the high strength and ductility of the steel. This makes steel stand out compared to concrete for earthquake resistant building design.The seismic performance of a multi-story steel frame structure is analyzed according to the provision of current Turkish Eartquake Code (DBYBHY 2018). Few guidelines like Applied Technology Council (ATC40) and Federal Emergency Management Agency (FEMA356) have used. Steel bracing is very useful for increasing the shear capacity of the structure. The use of steel brace is one of the most common methods to increase the earthquake resistance of buildings. In steel structures, the steel brace arrangement is arranged in two ways, concentric and eccentric. There are few possibilities to arrange steel bracings such as X, V, Diagonal, K (Concentric bracings) and some eccentric bracings as well. In this study typical 5 storey steel frame buildings have analyzed, for X and invert V types of concentric bracings. Performance of each frame is studied through pushover analysis. The pushover analysis has been carried out using SAP2000 v18, a product of computer and structure international. The results of all models are analyze and compare in term of base shear, story displacement, pushover curve, spectrum curve, performance point of the structure. en_US
dc.identifier.issn 2319-1813 en_US
dc.identifier.uri https://hdl.handle.net/20.500.13091/6118
dc.language.iso en en_US
dc.relation.ispartof The International Journal of Engineering and Science (IJES) en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Static Pushover Analysis en_US
dc.subject Steel Structures Sistems en_US
dc.subject Earthquake Loads en_US
dc.subject Braced Steel Structures en_US
dc.title Static Push Over Analysis of a 5 Storey Steel Building en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id 0000-0002-2461-132X
gdc.author.institutional Köken, Ali
gdc.coar.access open access
gdc.coar.type text::journal::journal article
gdc.contributor.affiliation Fakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, İnşaat Mühendisliği Bölümü en_US
gdc.contributor.affiliation #PLACEHOLDER_PARENT_METADATA_VALUE# en_US
gdc.description.department Fakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, İnşaat Mühendisliği Bölümü en_US
gdc.description.endpage 35 en_US
gdc.description.issue 12 en_US
gdc.description.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
gdc.description.scopusquality N/A
gdc.description.startpage 28 en_US
gdc.description.volume 9 en_US
gdc.description.wosquality N/A
gdc.virtual.author Köken, Ali
relation.isAuthorOfPublication d36ae4f9-893b-4c93-a658-373f454caf6b
relation.isAuthorOfPublication.latestForDiscovery d36ae4f9-893b-4c93-a658-373f454caf6b

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
E0912022835.pdf
Size:
874.32 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.2 KB
Format:
Item-specific license agreed upon to submission
Description: