Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/565
Full metadata record
DC FieldValueLanguage
dc.contributor.authorErkan, İbrahim Hakkı-
dc.contributor.authorDoğan, Talha Polat-
dc.contributor.authorArslan, Musa Hakan-
dc.date.accessioned2021-12-13T10:26:56Z-
dc.date.available2021-12-13T10:26:56Z-
dc.date.issued2020-
dc.identifier.issn2149-8024-
dc.identifier.issn2149-8024-
dc.identifier.urihttps://doi.org/10.20528/cjsmec.2020.01.001-
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TXpjeU16RTRPQT09-
dc.identifier.urihttps://hdl.handle.net/20.500.13091/565-
dc.description.abstractReinforced concrete walls are very efficient structural elements in terms of carrying the lateral loads that are expected to affect the structures during the service of the buildings. These elements, which are not used for economic reasons in buildings designed in areas with low seismic hazard, can actually provide a significant increase in performance with a very small increase in construction cost. In this study, a total of 9 building models have been created and the relationship between optimum reinforced concrete wall ratio and cost on these buildings has been investigated. The design and analysis of the models were carried out according to the criteria specified in TSC 2018. Three different structural systems specified in TSC 2018 were used in the designed models. These structural systems used; RC frame structures, RC wall-frame structures and RC wall structures. These structures were analyzed by Response Spectrum Method which is linear analysis method and base shear forces were obtained. Then, push-over analysis, which is a nonlinear analysis method, was applied to obtain the base shear forces that the structure can actually carry. After the analysis, the quantities of materials to be used for the construction of the structural systems of the models were calculated and current manufacturing prices and rough costs were calculated. In order to compare the obtained costs with the structural performances, nonlinear shear forces and linear shear forces ratios were calculated and the over strength factors were calculated for each model. In the light of the data obtained from the studies in the literature, when the over strength factors and cost values are examined together, it is concluded that the optimum design for the conditions specified in TSC 2018 will be provided with the RC wall ratio between 0.001 - 0.0016. It is concluded that lateral load carrying capacity of construction increases up to 650% by increasing the construction cost by 17% for the designed models.en_US
dc.language.isoenen_US
dc.relation.ispartofChallenge Journal of Structural Mechanicsen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleAn investigation on determining optimum wall ratio–cost relationship of shear walled reinforced concrete buildingsen_US
dc.typeArticleen_US
dc.identifier.doi10.20528/cjsmec.2020.01.001-
dc.departmentFakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.identifier.volume6en_US
dc.identifier.issue1en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.trdizinid372318en_US
item.languageiso639-1en-
item.fulltextWith Fulltext-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.author.dept02.02. Department of Civil Engineering-
crisitem.author.dept02.02. Department of Civil Engineering-
Appears in Collections:Mühendislik ve Doğa Bilimleri Fakültesi Koleksiyonu
TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collections
Files in This Item:
File SizeFormat 
16e6b689-ad66-4761-ba55-c81496d91ecc.pdf1.15 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

106
checked on Apr 22, 2024

Download(s)

60
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.