Title: Code-based damage assessment of existing precast industrial buildings following the February 6th, 2023 Kahramanmaraş earthquakes (Pazarcık Mw 7.7 and Elbistan Mw7.6)
Authors: Arslan, M.H.
Dere, Y.
Ecemiş, A.S.
Doğan, G.
Özturk, M.
Korkmaz, S.Z.
Keywords: Connection
Damage
Kahramanmaraş earthquake
Prefabricated industrial buildings
Damage detection
Finite element method
Industrial research
Losses
Mortar
Office buildings
Structural analysis
Connection
Damage
Damage assessments
Economic loss
Industrial buildings
Industrial facilities
Kahramanmaraş earthquake
Pre-cast
Precast structure
Prefabricated industrial building
Earthquakes
Publisher: Elsevier Ltd
Abstract: In Turkey, a substantial portion of the industrial buildings consists of precast structures. Unfortunately, these buildings suffered significant damage, with some partially collapsing, during two consecutive earthquakes that occurred in Kahramanmaraş (Pazarcık Mw7.7 and Elbistan Mw7.6) on February 6, 2023. Consequently, numerous industrial facilities became unusable, leading to substantial economic losses. This article aims to identify the vulnerabilities of such buildings and assess their actual earthquake performance to prevent potential future damages. The authors collected data through field investigations conducted near the earthquake's epicenter, which were subsequently evaluated within the study. The research comprehensively examines the seismic characteristics of both earthquakes, the structural system of existing prefabricated industrial buildings in the region, and the relevant provisions outlined in the history of earthquake codes for prefabricated industrial buildings. Additionally, nonlinear finite element simulations of the heavily damaged hinged type of column-beam connections commonly employed in earthquake-prone areas are presented. The impact of manufacturing defects on the structural seismic behavior is also investigated. In the study's final stage, it is concluded that non-compliance with structural projects and relevant codes during the manufacture of connection regions in prefabricated industrial buildings is one of the primary causes of structural damage. Furthermore, it is observed that necessary measures should be implemented in these structures to enhance lateral stiffness in the roof plane, and the use of hinged column-beam joints should be avoided or restricted, especially in regions prone to earthquakes. The finite element model analysis reveals that the load-bearing capacity of the connection increases by 62% for lateral out-of-plane loading when grout mortar is applied. © 2024 Elsevier Ltd
URI: https://doi.org/10.1016/j.jobe.2024.108811
https://hdl.handle.net/20.500.13091/5396
ISSN: 2352-7102
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collections

Show full item record



CORE Recommender

Page view(s)

2
checked on May 6, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.