dc.description.abstractIn knee prostheses, the curve of the instantaneous center of rotation (ICR) and, therefore, stability of the prothesis are the most important parameters to be considered. The ICR curve depends on many parameters. One of them and the most effective one is the dimensions of four bar mechanism. In polycentric knee mechanisms, it has become inevitable to use optimization techniques while determining the dimensions of the mechanism for the stability of the prosthesis in the stance position. In this study, definitions of knee prostheses and polycentric knee mechanisms are given, optimization studies written in this field are mentioned thorough literature research. The study aims to find mechanism dimensions that gives ICR curve close to the reference curve by optimizing the mechanism dimensions of four-bar knee mechanisms. The Bees Algorithm and Genetic Algorithm (GA) were used for this purpose. The limits and objective function for the optimization were determined, and after many trials, separate mechanism dimensions with The Bees Algorithm and the Genetic Algorithm are obtained. By comparing the results, it has been observed that the dimensions obtained by The Bees Algorithm produced a better approximation to the reference instantaneous center of rotation curve.en_US
dc.language.isoenen_US
dc.relation.ispartofJournal of Materials and Mechatronics:A (Online)en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleDimension Optimization of Polycentric Knee Mechanism Using the Bees Algorithm and Genetic Algorithmen_US
dc.typeArticleen_US
dc.identifier.doi10.55546/jmm.1243744-
dc.departmentKTÜNen_US
dc.identifier.volume4en_US
dc.identifier.issue1en_US
dc.identifier.startpage318en_US
dc.identifier.endpage332en_US
dc.institutionauthor-
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.trdizinid1182672en_US
item.grantfulltextopen-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeArticle-
crisitem.author.dept02.10. Department of Mechanical Engineering-
crisitem.author.dept02.10. Department of Mechanical Engineering-
crisitem.author.dept02.10. Department of Mechanical Engineering-
crisitem.author.dept02.10. Department of Mechanical Engineering-
Appears in Collections:TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collections
Files in This Item:
File SizeFormat 
10.55546-jmm.1243744-2922886.pdf1.12 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

168
checked on May 6, 2024

Download(s)

62
checked on May 6, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.