Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/4494
Full metadata record
DC FieldValueLanguage
dc.contributor.authorİspir, Murat-
dc.contributor.authorBakırhan, Mahmud-
dc.contributor.authorAksoy, Muharrem Hilmi-
dc.date.accessioned2023-08-03T19:03:56Z-
dc.date.available2023-08-03T19:03:56Z-
dc.date.issued2023-
dc.identifier.issn1694-7398-
dc.identifier.urihttps://doi.org/10.51354/mjen.1223399-
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/1185317-
dc.identifier.urihttps://hdl.handle.net/20.500.13091/4494-
dc.description.abstractThe installation of photovoltaic (PV) panels on building roofs has seen a significant increase in recent years due to the rising cost of conventional energy sources. This shift towards renewable energy sources has been driven by the urgent need to mitigate the effects of climate change. PV applications is one of the most sustainable and cleanest sources of renewable energy, producing no greenhouse gas emissions during operation. By reducing reliance on fossil fuels, the use of PV panels can help to reduce carbon emissions and lower the overall carbon footprint of buildings. In addition to the environmental benefits, the installation of PV panels can also provide economic benefits, such as reduced energy costs and increased property value. In the past, installations were mostly made in the direction of the south, but now the roofs of the buildings facing west, east, and even north are also considered for PV panel installations. In this study, a grid-connected PV system with an installed power of 148 kWp at the Konya Technical University (KTUN) campus is modeled by PVsyst software. The PV systems' performance on building roofs oriented in different geographical directions (north, south, east, and west) with a 30° fixed tilt angle was investigated. In the modeling, the solar irradiation coming to the surfaces of the PV panels, electricity production values, performance ratios, and their economic feasibility were calculated. The highest effective irradiation value on the panel surface was obtained from the system facing south, found as 1964.4 kWh/m². It is 20.77%, 22.87%, and 73.48% higher than the solar irradiation obtained at -90°, +90°, and 180° azimuth angles, respectively. It is concluded that the electricity generation amounts of PV systems highly depend on the azimuth angle. Similarly, the highest annual electricity production was obtained from the system installed in the 0° azimuth angle found as 254.77 MWh. The annual total electricity generation is 19.66%, 22.55%, and 69.41% higher in systems modeled toward the east, west, and north, respectively. Performance ratio, defined as the ratio of radiation coming to the panel surface and the electricity produced, has relative values between 0.843 and 0.862 for four different azimuth angles. Furthermore, as an economic analysis, the Basic Payback Period (BPP) of the projects was found as 6.92 years, 4.08 years, 4.88 years, and 5.00 years for the systems modeled in the north, south, east, and west directions, respectively. It can be concluded that the most suitable orientation is south, and the other two directions, east, and west, can also be considered feasible.en_US
dc.language.isoenen_US
dc.relation.ispartofManas Journal of Engineeringen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleAnalysis of the azimuth angles of a medium-scale PV system in non-ideal positions for roof applicationen_US
dc.typeArticleen_US
dc.identifier.doi10.51354/mjen.1223399-
dc.departmentKTÜNen_US
dc.identifier.volume11en_US
dc.identifier.issue1en_US
dc.identifier.startpage74en_US
dc.identifier.endpage82en_US
dc.institutionauthor-
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.trdizinid1185317en_US
item.fulltextWith Fulltext-
item.openairetypeArticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.languageiso639-1en-
crisitem.author.dept02.10. Department of Mechanical Engineering-
Appears in Collections:TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collections
Files in This Item:
File SizeFormat 
document (9).pdf999.52 kBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

94
checked on May 13, 2024

Download(s)

14
checked on May 13, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.