dc.description.abstractThe 06 February 2023 Kahramanmaras, Earthquakes, which were the disaster of the century for Turkiye and in which more than 50,000 people lost their lives, caused many buildings to collapse or receive significant structural damages. Adiyaman is one of the provinces that caused the most destruction by earthquakes affecting 11 different provinces, which occupy approximately 14% of the country's surface area. The masonry buildings have been severely damaged by earthquakes, which constitute a significant part of the building stock in the province's rural areas. In this study, the region's seismicity and the spectral acceleration values of the last earthquakes were analyzed, and the distribution of building damages was given statistically. The main goal of this study is to determine the collapse and failure mechanisms of existing unreinforced masonry buildings in detail. The study also includes reconstruction strategies or retrofitting procedures to prevent damage to masonry structures in the region. Non-compliance with seismic design codes is the leading cause of damage in masonry buildings constructed by local craftsmen using low-strength wall and joint building materials. The usage of heavy earthen roofs, insufficient wall-wall, and wall-roof connections, lack of vertical and horizontal beams, poor workmanship, and insufficient interlocking between layers are the causes of structural damages observed in the field. At the end of the study, critical clauses in the current earthquake code were emphasized, and the precautions to be taken for existing and new design masonry buildings were also mentioned.en_US
dc.language.isoenen_US
dc.publisherPergamon-Elsevier Science Ltden_US
dc.relation.ispartofEngineering Failure Analysisen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectStructural failureen_US
dc.subjectEarthquakeen_US
dc.subjectMasonryen_US
dc.subjectDamage levelen_US
dc.subjectCollapseen_US
dc.subjectAdiyamanen_US
dc.subjectSeismic design codeen_US
dc.subjectEast Anatolian Faulten_US
dc.subjectDead-Sea Faulten_US
dc.subjectConstruction Failuresen_US
dc.subject2009 Laquilaen_US
dc.subjectPerformanceen_US
dc.subjectBehavioren_US
dc.subjectPakistanen_US
dc.titleStructural damages in masonry buildings in Adiyaman during the Kahramanmaras, (Turkiye) earthquakes (Mw 7.7 and Mw 7.6) on 06 February 2023en_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.engfailanal.2023.107405-
dc.identifier.scopus2-s2.0-85162167233en_US
dc.departmentKTÜNen_US
dc.authoridISIK, Ercan/0000-0001-8057-065X-
dc.identifier.volume151en_US
dc.identifier.wosWOS:001025197300001en_US
dc.institutionauthor-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid56779720400-
dc.authorscopusid57210155587-
dc.authorscopusid55880819100-
dc.authorscopusid57210157672-
dc.authorscopusid11940766700-
dc.authorscopusid57193686945-
dc.authorscopusid57211785800-
dc.identifier.scopusqualityQ1-
item.fulltextWith Fulltext-
item.grantfulltextembargo_20300101-
item.openairetypeArticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
item.cerifentitytypePublications-
crisitem.author.dept02.02. Department of Civil Engineering-
crisitem.author.dept02.02. Department of Civil Engineering-
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collections
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collections
Files in This Item:
File SizeFormat 
1-s2.0-S135063072300359X-main.pdf
  Until 2030-01-01
60.05 MBAdobe PDFView/Open    Request a copy
Show simple item record



CORE Recommender

WEB OF SCIENCETM
Citations

27
checked on Aug 10, 2024

Page view(s)

66
checked on Aug 12, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.