dc.description.abstractSince a major part of energy in cold climates is spent on heating, using alternative methods to heat buildings is of particular importance for buildings. Solar greenhouses are inactive building solutions that absorb solar energy to provide heating in the side spaces. Greenhouse efficiency depends on several factors. The research carried out so far has used these factors in the design of a solar greenhouse to reduce energy consumption, which has finally been compared with the non-applied state of this system. The purpose of this study is to investigate the physical characteristics such as “depth”, “protrusion”, “roof slope”, and “orientation” of solar greenhouses and the influence of each factor in different modes and hours in the cold climate of Tabriz. For this purpose, a simulation has been made using “Energy Plus” software. In the next step, the optimal modes of solar greenhouse design are presented by comparing the different states of each physical factor on the first and the middle day of each month in a 6-hours period. Research results show; increasing the surface while the sun is shining and using more depth when there is no sun will maintain indoor temperature. Also, using two or three-way greenhouses (east and south) increases the efficiency of the greenhouse by 30%. The roof slope has no effect on heating the room adjacent to the greenhouse. Also, the absence of protrusions helps adjust the room temperature relative to the outside environment by up to 20 %. No significant effect on temperature was observed in calculating the ratio of greenhouse area to room area in summer. But in the cold season, a large greenhouse area greatly impacts by up to 15 %.en_US
dc.language.isoenen_US
dc.publisherKonya Technical University Faculty of Architecture and Designen_US
dc.relation.ispartofICONARP International Journal of Architecture and Planningen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSolar greenhouseen_US
dc.subjectOptimal criteria for designen_US
dc.subjectCold climateen_US
dc.subjectEnergy consumptionen_US
dc.subjectResidential buildingsen_US
dc.titleEvaluation of Optimal Criteria for Designing Solar Greenhouses in Cold Climate Residential Buildings (Case Study: Tabriz, Iran)en_US
dc.typeArticleen_US
dc.identifier.doi10.15320/ICONARP.2023.241%20-
dc.relation.issn2147-9380en_US
dc.description.volume11en_US
dc.description.issue1en_US
dc.description.startpage249en_US
dc.description.endpage270en_US
dc.departmentKTÜNen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Başka Kurum Yazarıen_US
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.openairetypeArticle-
item.grantfulltextopen-
item.cerifentitytypePublications-
Appears in Collections:ICONARP - International Journal of Architecture and Planning
Show simple item record



CORE Recommender

Page view(s)

96
checked on May 20, 2024

Download(s)

78
checked on May 20, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.