dc.description.abstractOverhead lines are generally used for electrical energy transmission. Also, XLPE underground cable lines are generally used in the city center and the crowded areas to provide electrical safety, so high voltage underground cable lines are used together with overhead line in the transmission lines, and these lines are called as the mixed lines. The distance protection relays are used to determine the impedance based fault location according to the current and voltage magnitudes in the transmission lines. However, the fault location cannot be correctly detected in mixed transmission lines due to different characteristic impedance per unit length because the characteristic impedance of high voltage cable line is significantly different from overhead line. Thus, determinations of the fault section and location with the distance protection relays are difficult in the mixed transmission lines. In this study, 154 kV overhead transmission line and underground cable line are examined as the mixed transmission line for the distance protection relays. Phase to ground faults are created in the mixed transmission line, and overhead line section and underground cable section are simulated by using PSCAD/ EMTDC ™. The short circuit fault images are generated in the distance protection relay for the overhead transmission line and underground cable transmission line faults. The images include the R-X impedance diagram of the fault, and the R-X impedance diagram have been detected by applying image processing steps. The regression methods are used for prediction of the fault location, and the results of image processing are used as the input parameters for the training process of the regression methods. The results of regression methods are compared to select the most suitable method at the end of this study for forecasting of the fault location in transmission lines. When looking at the method and performance criteria used in the overhead transmission line fault location study, it is the Linear Regression (Robust Linear) method that gives the most accurate results with RMSE 0.017652. When looking at the method and performance criteria used in the underground cable transmission line fault location study, it is the Linear Regression (Stepwise Linear) method, which gives the most accurate results with RMSE 0.0060709. When the accuracy of the method was examined, it was seen that it was higher than other methods.en_US
dc.language.isoenen_US
dc.relation.ispartofAvrupa Bilim ve Teknoloji Dergisien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDistance Protection Relayen_US
dc.subjectMixed Transmission Linesen_US
dc.subjectShort Circuit Faultsen_US
dc.subjectFault Location Estimationen_US
dc.subjectRegression Learner Mesafe Koruma Rölesien_US
dc.subjectKarma İletim Hatlarıen_US
dc.subjectKısa Devre Arızalarıen_US
dc.subjectArıza Yeri Tahiminien_US
dc.subjectRegresyon Metotlarıen_US
dc.titleFault Location Estimation by Using Machine Learning Methods in Mixed Transmission Linesen_US
dc.typeArticleen_US
dc.identifier.doi10.31590/ejosat.802888-
dc.departmentFakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, Elektrik-Elektronik Mühendisliği Bölümüen_US
dc.identifier.volume0en_US
dc.identifier.issueEjosat Özel Sayı 2020 (ICCEES)en_US
dc.identifier.startpage245en_US
dc.identifier.endpage250en_US
dc.institutionauthorBudak, Serkan-
dc.institutionauthorAkbal, Bahadır-
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.trdizinid1135905en_US
item.languageiso639-1en-
item.fulltextWith Fulltext-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.author.dept02.04. Department of Electrical and Electronics Engineering-
crisitem.author.dept02.04. Department of Electrical and Electronics Engineering-
Appears in Collections:Mühendislik ve Doğa Bilimleri Fakültesi Koleksiyonu
TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collections
Files in This Item:
File SizeFormat 
10.31590-ejosat.802888-1319626.pdf818.13 kBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

56
checked on Apr 22, 2024

Download(s)

22
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.