Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/3242
Full metadata record
DC FieldValueLanguage
dc.contributor.authorYel, Nur Seda-
dc.contributor.authorArslan, Musa Hakan-
dc.contributor.authorAksoylu, Ceyhun-
dc.contributor.authorErkan, İbrahim Hakkı-
dc.contributor.authorArslan, Hatice Derya-
dc.contributor.authorIşık, Ercan-
dc.date.accessioned2022-11-28T16:57:10Z-
dc.date.available2022-11-28T16:57:10Z-
dc.date.issued2022-
dc.identifier.issn2075-5309-
dc.identifier.urihttps://doi.org/10.3390/buildings12101722-
dc.identifier.urihttps://doi.org/10.3390/buildings12101722-
dc.identifier.urihttps://hdl.handle.net/20.500.13091/3242-
dc.description.abstractIn this study, earthquake performance of the structures was tested which were modeled according to the minimum criteria of simplified analysis approach proposed in TBEC-2019. For this purpose, 144 reinforced-concrete building models were designed according to parameters such as earthquake design class, building height (number of storey), number of spans, soil type and three different simplified formulas suggested in the code. The level of structural performance of buildings models was determined by the linear (L) and nonlinear performance analysis (NL) methods that given in TBEC-2019. The base shear force, top displacements and over-strength factor (omega) of each structural model were obtained, and performance analysis was performed by comparatively. As a result of the structural analyses, it was seen that some of the buildings model designed according to minimum column sectional criteria given in simplified methods could not meet the suggested seismic performance level. While the number of structural models that provide the controlled damage (CD) level in the L analysis method is 44 (30.55%), it is 107 (74.3%) in the NL analysis method. The insufficient performance was obtained in both L and NL methods in models which have over-strength values below 3. It has been observed that multi-criteria of building performance are not met with the weakening of local soil conditions. It was also seen that the L method chosen in the performance analysis gave more conservative results with this study.en_US
dc.language.isoenen_US
dc.publisherMdpien_US
dc.relation.ispartofBuildingsen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectsimplified design rulesen_US
dc.subjectearthquakeen_US
dc.subjectlinear methoden_US
dc.subjectnonlinear methoden_US
dc.subjectperformance analysisen_US
dc.subjectSeismic Performanceen_US
dc.subjectTurkey Earthquakeen_US
dc.subjectAugust 17en_US
dc.subjectBuildingsen_US
dc.subjectDamageen_US
dc.subjectMarmaraen_US
dc.titleInvestigation of the Earthquake Performance Adequacy of Low-Rise RC Structures Designed According to the Simplified Design Rules in TBEC-2019en_US
dc.typeArticleen_US
dc.identifier.doi10.3390/buildings12101722-
dc.identifier.scopus2-s2.0-85140634535en_US
dc.departmentFakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.authoridAksoylu, Ceyhun/0000-0002-1574-4251-
dc.authoridISIK, Ercan/0000-0001-8057-065X-
dc.identifier.volume12en_US
dc.identifier.issue10en_US
dc.identifier.wosWOS:000872667400001en_US
dc.institutionauthorYel, Nur Seda-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid57941895800-
dc.authorscopusid11940766700-
dc.authorscopusid57193686945-
dc.authorscopusid55609015200-
dc.authorscopusid57198158757-
dc.authorscopusid56779720400-
dc.identifier.scopusqualityQ1-
item.languageiso639-1en-
item.fulltextWith Fulltext-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.author.dept02.02. Department of Civil Engineering-
crisitem.author.dept02.02. Department of Civil Engineering-
crisitem.author.dept02.02. Department of Civil Engineering-
Appears in Collections:Mühendislik ve Doğa Bilimleri Fakültesi Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collections
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collections
Files in This Item:
File SizeFormat 
buildings-12-01722 (1).pdf6.73 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

WEB OF SCIENCETM
Citations

6
checked on Apr 20, 2024

Page view(s)

252
checked on Apr 22, 2024

Download(s)

362
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.