dc.description.abstractOne of the important parameters that affect the behavior of the reinforced concrete (RC) members under impact loading is the impactor geometry used for applying impact loading. It is known that changes in the impactor geometry have significant effects on energy transfer to the structural system, deformation distribution, and damage on structural members caused by impact loading. However, there is no encounter with a study with a detailed and comprehensive conclusion on this topic during the literature review. The lack of this kind of conclusion leads to an experimental study with different impactor geometries applying impact loading on RC slabs. These experiments examine the effects of impactor geometry on acceleration-time, displacement-time, impact loading-time, and maximum strain-time behaviors. In addition to those, effects on damage distribution and impact loading behaviors are examined. This study uses three flat-surfaced hammers with different surface areas and a hemispherical hammer. Impact loading is applied at two different magnitudes on specimens. Ls-Dyna software is also used to do numerical analysis for the members. Outputs of the analysis are compared with the experimental results to evaluate the modeling of effects of change in impactor geometry. When the results obtained as a result of the experimental study were examined, it was seen that the change in the geometry of the impactor to which the impact loading was applied significantly changed the behavior of the slabs under the impact loading. The increase in the impactor contact area caused an increase in the impact loading applied to the specimens, and the acceleration, displacement, residual displacement, and strain values measured from the specimens all increased.en_US
dc.description.sponsorshipEskisehir Osmangazi University's Scientific Research Projects Department [2020-15006, 178]; Osmangazi Universityen_US
dc.description.sponsorshipThis study is supported by Eskisehir Osmangazi University's Scientific Research Projects Department (Project Number: 2020-15006 and Project ID: 178) . The authors would like to thank Osmangazi University for their support.en_US
dc.language.isoenen_US
dc.publisherElsevier Sci Ltden_US
dc.relation.ispartofEngineering Structuresen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectRC Slaben_US
dc.subjectImpacten_US
dc.subjectImpactor Geometryen_US
dc.subjectContact Surface Areaen_US
dc.subjectLS-Dynaen_US
dc.subjectNumerical-Simulationen_US
dc.subjectRc Panelsen_US
dc.subjectResistanceen_US
dc.subjectDamageen_US
dc.subjectResponsesen_US
dc.subjectColumnsen_US
dc.subjectModelen_US
dc.titleInvestigation of the effects of impactor geometry on impact behavior of reinforced concrete slabsen_US
dc.typeArticleen_US
dc.identifier.doi10.1016/j.engstruct.2022.114429-
dc.identifier.scopus2-s2.0-85130572606en_US
dc.departmentFakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.authoridYilmaz, Tolga/0000-0001-7668-1496-
dc.authorwosidYilmaz, Tolga/ABD-7319-2021-
dc.identifier.volume263en_US
dc.identifier.wosWOS:000806565000006en_US
dc.institutionauthorŞengel, Selim-
dc.institutionauthorErol, Hakan-
dc.institutionauthorYılmaz, Tolga-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid57704218100-
dc.authorscopusid37017254500-
dc.authorscopusid57188968298-
dc.authorscopusid6508251680-
dc.identifier.scopusqualityQ1-
item.grantfulltextembargo_20300101-
item.openairetypeArticle-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
item.cerifentitytypePublications-
crisitem.author.dept02.02. Department of Civil Engineering-
Appears in Collections:Mühendislik ve Doğa Bilimleri Fakültesi Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collections
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collections
Files in This Item:
File SizeFormat 
1-s2.0-S0141029622005405-main.pdf
  Until 2030-01-01
14.46 MBAdobe PDFView/Open    Request a copy
Show simple item record



CORE Recommender

WEB OF SCIENCETM
Citations

11
checked on May 4, 2024

Page view(s)

108
checked on Apr 29, 2024

Download(s)

6
checked on Apr 29, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.