Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/2979
Title: Behavior of CFRP-strengthened RC beams with circular web openings in shear zones: Numerical study
Authors: Özkılıç, Yasin Onuralp
Aksoylu, Ceyhun
Yazman, Şakir
Gemi, Lokman
Arslan, Musa Hakan
Keywords: CFRP
Circular opening
Failure modes
Reinforced concrete beam
Shear damage
Reinforced-Concrete Beams
Tubular T-Joints
Flexural Behavior
R/C Beams
Deep Beams
Performance
Design
Tests
Publisher: Elsevier Science Inc
Abstract: In practice, especially the basement floor beams are drilled and damaged by the users. In some cases, this damage to the beams can be significant for the load-bearing element and the whole structure. In this study, the behavior of reinforced concrete beams with circular openings and the failure types resulting from strengthening these beams with CFRP are parametrically investigated. The diameter of the opening/beam height ratio (D/H), con-crete compressive strength, stirrup spacing, the position of the opening to the beam support, the type of CFRP application, CFRP ply orientation, and the number of CFRP layers were selected as parameters. Numerical models were verified using 9 specimens having different circular openings with/without CFRP strengthening and the analyses of 95 numerical models with the selected parameters were carried out utilizing the finite element program, ABAQUS. The ultimate load capacity, ductility, stiffness, energy dissipation capacity and failure modes of the beams were determined. As a result of the study, it was observed that there was no significant loss in ductility for the beams with D/H < 0.3 and the number of CFRP layer and type of application did not have a significant effect on D/H < 0.44. However, for the beams with D/H > 0.64, the CFRP application that completely surrounds openings should be preferred instead of partial CFRP strengthening. In addition, the concrete strength is an effective parameter for the beams with D/H < 0.44. The effect of the stirrup spacings in the beam on the ductile behavior was also limited with the increase in the hole diameter. The number of CFRP layers should theoretically be 4 for an effective strengthening in beams with D/H > 0.44. Finally, U wrapping is recommended instead of using full wrapping. It has been seen that the location and diameter of the hole are very important parameters in the failure type of the beam.
URI: https://doi.org/10.1016/j.istruc.2022.05.061
https://hdl.handle.net/20.500.13091/2979
ISSN: 2352-0124
Appears in Collections:Mühendislik ve Doğa Bilimleri Fakültesi Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collections
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collections

Files in This Item:
File SizeFormat 
1-s2.0-S2352012422004234-main.pdf
  Until 2030-01-01
31.54 MBAdobe PDFView/Open    Request a copy
Show full item record



CORE Recommender

SCOPUSTM   
Citations

4
checked on Apr 20, 2024

WEB OF SCIENCETM
Citations

50
checked on Apr 20, 2024

Page view(s)

96
checked on Apr 22, 2024

Download(s)

6
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.