Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/2976
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGemi, Lokman-
dc.contributor.authorAlsdudi, Mohammed-
dc.contributor.authorAksoylu, Ceyhun-
dc.contributor.authorYazman, Şakir-
dc.contributor.authorÖzkılıç, Yasin Onuralp-
dc.contributor.authorArslan, Musa Hakan-
dc.date.accessioned2022-10-08T20:50:02Z-
dc.date.available2022-10-08T20:50:02Z-
dc.date.issued2022-
dc.identifier.issn1229-9367-
dc.identifier.issn1598-6233-
dc.identifier.urihttps://doi.org/10.12989/scs.2022.43.6.735-
dc.identifier.urihttps://hdl.handle.net/20.500.13091/2976-
dc.description.abstractThe behavior of shear deficient under-balanced reinforced concrete beams with rectangular cross-sections, which were externally strengthened with CFRP composite along shear spans, was experimentally investigated under vertical load. One of the specimens represents a reference beam without CFRP strengthening and the other specimens have different width/strip spacing ratios (w(f)/s(f)). The optimum strip in terms of w(f)/s(f), which will bring the beam behavior to the ideal level in terms of strength and ductility, was determined according to the regulations. When the w(f)/s(f) ratio exceeds 0.55, the behavior of the beam shifted from shear failure to bending failure. However, it has been observed that the w(f)/s(f) ratio should be increased up to 0.82 in order for the beam to reach sufficient shear reserve value according to the codes. It is also observed that the direction and weight of the CFRP composite are one of the most critical factors and 240 gr/m(2) CFRP strips experienced sudden ruptures in the shear span after the cracking of the concrete. It is considered as a deficiency that the empirical shear capacity formulas given for the beams reinforced with CFRP in the regulations do not take into account both direction and weight of CFRP composites.en_US
dc.description.sponsorshipKonya Technical University BAP [201004038]en_US
dc.description.sponsorshipAuthors especially would like to thank Konya Technical University BAP (Project Number: 201004038).en_US
dc.language.isoenen_US
dc.publisherTechno-Pressen_US
dc.relation.ispartofSteel and Composite Structuresen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCFRP compositeen_US
dc.subjectdamage history analysisen_US
dc.subjectOptimum FRPen_US
dc.subjectreinforced concrete beamen_US
dc.subjectshear deficienten_US
dc.subjectstrengtheningen_US
dc.subjectRc Beamsen_US
dc.subjectDeep Beamsen_US
dc.subjectT-Beamsen_US
dc.subjectFailure Analysisen_US
dc.subjectFrp Sheetsen_US
dc.subjectBehavioren_US
dc.subjectPerformanceen_US
dc.subjectGfrpen_US
dc.subjectDamageen_US
dc.subjectCompositesen_US
dc.titleOptimum amount of CFRP for strengthening shear deficient reinforced concrete beamsen_US
dc.typeArticleen_US
dc.identifier.doi10.12989/scs.2022.43.6.735-
dc.identifier.scopus2-s2.0-85136072167en_US
dc.departmentFakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.authoridGemi, Lokman/0000-0002-9895-6574-
dc.authoridÖzkılıç, Yasin Onuralp/0000-0001-9354-4784-
dc.authorwosidGemi, Lokman/AAD-2271-2020-
dc.authorwosidÖzkılıç, Yasin Onuralp/AAA-9279-2019-
dc.identifier.volume43en_US
dc.identifier.issue6en_US
dc.identifier.startpage735en_US
dc.identifier.endpage757en_US
dc.identifier.wosWOS:000827432600004en_US
dc.institutionauthorAlsdudi, Mohammed-
dc.institutionauthorAksoylu, Ceyhun-
dc.institutionauthorArslan, Musa Hakan-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.scopusqualityQ1-
item.languageiso639-1en-
item.fulltextNo Fulltext-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.author.dept02.02. Department of Civil Engineering-
crisitem.author.dept02.02. Department of Civil Engineering-
Appears in Collections:Mühendislik ve Doğa Bilimleri Fakültesi Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collections
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collections
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

34
checked on Apr 20, 2024

WEB OF SCIENCETM
Citations

34
checked on Apr 20, 2024

Page view(s)

710
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.