Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/2161
Full metadata record
DC FieldValueLanguage
dc.contributor.authorEndiz, Mustafa Sacid-
dc.date.accessioned2022-02-26T20:58:16Z-
dc.date.available2022-02-26T20:58:16Z-
dc.date.issued2021-
dc.identifier.issn2667-8055-
dc.identifier.urihttps://doi.org/10.36306/konjes.970208-
dc.identifier.urihttps://dergipark.org.tr/tr/pub/konjes/issue/64647/970208-
dc.identifier.urihttps://dergipark.org.tr/tr/download/article-file/1876397-
dc.identifier.urihttps://hdl.handle.net/20.500.13091/2161-
dc.descriptionDergiPark: 970208en_US
dc.descriptionkonjesen_US
dc.description.abstractGeleneksel akım ve gerilim kaynaklı inverterler, DC-AC güç dönüşümünde girişine uygulanan gerilimi yükseltmek için DC-DC dönüştürücü veya trafoya ihtiyaç duymaktadır. Bu ihtiyacı ortadan kaldırmak amacıyla son yıllarda sıklıkla kullanılan empedans kaynaklı inverter (ZSI) devresi önerilmiştir. ZSI devresi, sahip olduğu empedans katı ve kısa devre çalışabilme özelliği sayesinde DC giriş gerilim değerini istenilen değere dönüştürebilmektedir. Bu çalışmada, ZSI’nin dezavantajlarını ortadan kaldırarak daha verimli DC-AC güç dönüşümü yapabilen T-Kaynak inverter (TSI) devresi, Matlab/Simulink ortamında farklı devre parametreleri için incelenmiştir. TSI devresinin yapısı ve çalışma prensibi, ilgili denklemler kullanılarak teorik olarak açıklanmıştır. TSI devre yapısı, ZSI’de olduğu gibi aynı faz kolundaki anahtarlama elemanlarını kısa devre ederek DC giriş gerilimini yükseltme özelliğine sahiptir. Kullanılan modülasyon indeksine ve kısa devre görev oranına bağlı olarak, TSI devresi düşürücü-yükseltici olarak çalışabilmektedir. Güç katındaki anahtarlama elemanlarını sürmek için sinüzoidal PWM tabanlı maksimum yükseltici kontrol tekniği uygulanmıştır. TSI’nin belirli bir kısa devre çalışma oranında ve DC giriş gerilim değerinde; DC hat gerilimi, kondansatör ve AC çıkış gerilim değeri, ZSI devresi ile karşılaştırmalı olarak hesaplanmıştır. Benzetim çalışmaları ile teorik sonuçların örtüştüğü görülmüş, TSI devresinin ZSI’ye kıyasla daha az pasif devre elemanı kullanarak etkin şekilde DC-AC güç dönüşümü yapabileceği gösterilmiştir.en_US
dc.description.abstractConventional current and voltage source inverters need a DC-DC converter or transformer to increase the applied voltage in DC-AC conversion. In order to eliminate this need, Z-Source inverter (ZSI), which has been used frequently in recent years, has been proposed. The ZSI circuit can convert DC input voltage to the desired value using its Z-Network and short-circuit capability. In this study, T-Source inverter (TSI), which can make more efficient DC-AC conversion by eliminating the disadvantages of ZSI, is examined using Matlab/Simulink for different circuit parameters. The working principle of TSI circuit is explained theoretically by using related equations. TSI network is able to increase DC voltage by short- circuiting the switching elements in the same phase leg as in ZSI. Depending on the applied modulation index and shoot-through duty ratio, TSI can operate as a buck-boost converter. PWM based maximum boost control technique is employed to drive the switching elements. Compared to ZSI; DC-link voltage, capacitor and AC output voltage of TSI are calculated at a certain shoot-through duty ratio and DC input voltage. It has been shown that the theoretical results match with the simulation studies, and TSI circuit can effectively perform DC-AC conversion using less passive circuit elements compared to ZSI.en_US
dc.language.isotren_US
dc.publisherKonya Technical Universityen_US
dc.relation.ispartofKonya Mühendislik Bilimleri Dergisien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectT-Kaynak inverteren_US
dc.subjectMaksimum Yükseltici Kontrolen_US
dc.subjectYükseltme faktörüen_US
dc.subjectZSIen_US
dc.subjectT-Source inverteren_US
dc.subjectMaximum Boost Controlen_US
dc.subjectBoost factoren_US
dc.subjectZSIen_US
dc.titleMAKSİMUM YÜKSELTİCİ KONTROLLÜ T-KAYNAK İNVERTERİN ANALİZİen_US
dc.title.alternativeAnalysis of T-Source Inverter with Maximum Boost Controlen_US
dc.typeArticleen_US
dc.identifier.doi10.36306/konjes.970208-
dc.departmentKTÜNen_US
dc.identifier.volume9en_US
dc.identifier.issue3en_US
dc.identifier.startpage753en_US
dc.identifier.endpage765en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Başka Kurum Yazarıen_US
item.grantfulltextopen-
item.fulltextWith Fulltext-
item.languageiso639-1tr-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeArticle-
Appears in Collections:Konya Mühendislik Bilimleri Dergisi
Files in This Item:
File SizeFormat 
10.36306-konjes.970208-1876397.pdf1.47 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

90
checked on May 6, 2024

Download(s)

38
checked on May 6, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.