Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/1984
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBudak, Serkan-
dc.contributor.authorAkbal, Bahadır-
dc.date.accessioned2022-02-26T20:54:19Z-
dc.date.available2022-02-26T20:54:19Z-
dc.date.issued2020-
dc.identifier.issn2667-8055-
dc.identifier.urihttps://doi.org/10.36306/konjes.821726-
dc.identifier.urihttps://dergipark.org.tr/tr/pub/konjes/issue/58996/821726-
dc.identifier.urihttps://dergipark.org.tr/tr/download/article-file/1381781-
dc.identifier.urihttps://hdl.handle.net/20.500.13091/1984-
dc.descriptionDergiPark: 821726en_US
dc.descriptionkonjesen_US
dc.description.abstractHavai hatlar genellikle elektrik enerjisi iletimi için kullanılır. Ayrıca XLPE yeraltı kablo hatları genellikle şehir merkezinde ve kalabalık alanlarda elektrik güvenliğini sağlamak için kullanılır, bu nedenle iletim hatlarında havai hat ile birlikte yüksek gerilim yeraltı kablo hatları kullanılır ve bu hatlar karma hatları olarak adlandırılır. Mesafe koruma röleleri, iletim hatlarındaki akım ve gerilim büyüklüklerine göre empedans tabanlı ölçüm sonucu arıza yerini belirler. Ancak yüksek gerilim kablo hattının karakteristik empedansı havai hattan önemli ölçüde farklı olduğundan, birim uzunluk başına farklı karakteristik empedans nedeniyle karma iletim hatlarında arıza konumu doğru bir şekilde tespit edilemez. Bu nedenle karma iletim hatlarında mesafe koruma röleleri ile arıza bölümünün ve yerinin tespiti zordur. Bu çalışmada, 154 kV havai iletim hattı ve yer altı kablo hattı, mesafe koruma röleleri için karma iletim hattı olarak incelenmiştir. Karma iletim hattında faz-toprak arızaları oluşturulur ve havai hat bölümü ve yeraltı kablo bölümü PSCAD / EMTDC ™ kullanılarak benzetimi yapılmıştır. Kısa devre arıza görüntüleri, havai iletim hattı ve yer altı kablo iletim hattı arızaları için mesafe koruma rölesinde oluşturulur. Görüntüler, arızanın R-X empedans diyagramını içerir ve R-X empedans diyagramından elde edilen görüntüler görüntü işleme adımları uygulanmıştır. Arıza yeri tahmini için görüntü işleme sonuçlarından çıkarılan özellikler giriş parametresi olarak belirlenmiştir. Yapay sinir ağları (YSA) ve regresyon yöntemleri kullanılarak arıza yeri tahmini yapılmıştır. YSA sonuçları ve regresyon yöntemleri bu çalışmanın sonunda iletim hatlarında arıza yerinin tahmin edilmesi için en uygun yöntemin seçilmesi için karşılaştırılmıştır.en_US
dc.description.abstractOverhead lines are generally used for electrical energy transmission. Also, XLPE underground cable lines are generally used in the city center and the crowded areas to provide electrical safety, so high voltage underground cable lines are used together with overhead line in the transmission lines, and these lines are called as the mixed lines. The distance protection relays are used to determine the impedance based fault location according to the current and voltage magnitudes in the transmission lines. However, the fault location cannot be correctly detected in mixed transmission lines due to different characteristic impedance per unit length because the characteristic impedance of high voltage cable line is significantly different from overhead line. Thus, determinations of the fault section and location with the distance protection relays are difficult in the mixed transmission lines. In this study, 154 kV overhead transmission line and underground cable line are examined as the mixed transmission line for the distance protection relays. Phase to ground faults are created in the mixed transmission line. overhead line section and underground cable section are simulated by using PSCAD/ EMTDC ™. The short circuit fault images are generated in the distance protection relay for the overhead transmission line and underground cable transmission line faults. The images include the R-X impedance diagram of the fault, and the R-X impedance diagram have been detected by applying image processing steps. Artificial neural network (ANN) and the regression methods are used for prediction of the fault location, and the results of image processing are used as the input parameters for the training process of ANN and the regression methods. The results of ANN and regression methods are compared to select the most suitable method at the end of this study for forecasting of the fault location in transmission lines.en_US
dc.language.isotren_US
dc.publisherKonya Technical Universityen_US
dc.relation.ispartofKonya Mühendislik Bilimleri Dergisien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMesafe koruma rölesien_US
dc.subjectKarma iletim hatlarıen_US
dc.subjectKısa devre arızalarıen_US
dc.subjectRegresyon metotlarıen_US
dc.subjectArıza yeri tahminien_US
dc.subjectYapay sinir ağlarıen_US
dc.subjectDistance protection relayen_US
dc.subjectMixed transmission linesen_US
dc.subjectShort circuit faultsen_US
dc.subjectMatlab regression learneren_US
dc.subjectFault location estimationen_US
dc.subjectArtificial neural networken_US
dc.titleKarma İletim Hatlarında Görüntü İşleme Kullanılarak Karşılaştırmalı Hata Konumu Tahminien_US
dc.title.alternativeCOMPARATIVE FAULT LOCATION ESTIMATION BY USING IMAGE PROCESSING IN MIXED TRANSMISSION LINESen_US
dc.typeArticleen_US
dc.identifier.doi10.36306/konjes.821726-
dc.departmentFakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, Elektrik-Elektronik Mühendisliği Bölümüen_US
dc.identifier.volume8en_US
dc.identifier.startpage62en_US
dc.identifier.endpage75en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.trdizinid491285en_US
item.grantfulltextopen-
item.openairetypeArticle-
item.fulltextWith Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1tr-
item.cerifentitytypePublications-
crisitem.author.dept02.04. Department of Electrical and Electronics Engineering-
crisitem.author.dept02.04. Department of Electrical and Electronics Engineering-
Appears in Collections:Konya Mühendislik Bilimleri Dergisi
Mühendislik ve Doğa Bilimleri Fakültesi Koleksiyonu
TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collections
Files in This Item:
File SizeFormat 
10.36306-konjes.821726-1381781.pdf815.68 kBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

142
checked on Apr 29, 2024

Download(s)

80
checked on Apr 29, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.