Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/1204
Title: NEWTON TİPİ OLMAYAN AKIŞKAN KULLANARAK KALP DESTEK POMPASININ PERFORMANSININ HESAPLAMALI AKIŞKANLAR MEKANİĞİ YÖNTEMİ İLE İNCELENMESİ
Other Titles: EXPERIMENTAL AND NUMERICAL DETERMINATION OF THE PERFORMANCE OF HEART ASSIST PUMP USING A NONNEWTONIAN FLUID
Authors: Sabah, Ahmet
Yapıcı, Rafet
Abstract: Kalp rahatsızlıkları içerisinde önemli bir yere sahip olan kalp yetmezliği, insan kalbinin çeşitli nedenlerden dolayı vücuda ihtiyaç duyduğu yeterli kanı pompalayamaması durumudur. Bu hastalığa sahip bireylere yardımcı olmak amacıyla ventriküler (karıncık) destek cihazları (VAD) adı verilen mekanik sistemler geliştirilmiştir. Sol ventriküler destek cihazları, kalbin sol karıncığından kanın aort atar damarına pompalamasına yardımcı olmaktadır. Bu çalışmada, tasarlanmış olan karışık akışlı bir sol ventriküler kalp destek pompasının hidrodinamik performansı hesaplamalı akışkanlar dinamiği (HAD) metodu ile belirlenmiştir. Analizlerde çalışma akışkanı olarak kana benzer reolojik özellikler gösteren newtoniyen olmayan su-ksantan karışımı (kütlece %0.06 ksantan sakızı) kullanılmıştır. 5000, 6000 ve 7000 dev/dak dönme hızlarında pompanın debisine bağlı olarak basıncını ve verimini gösteren performans eğrileri elde edilmiştir. Sonuçların karşılaştırılması amacıyla newtoniyen bir akışkan olan su-gliserin çözeltisi (hacimce %40 gliserin ve %60 su) ile de HAD analizleri yapılmıştır. Pompanın sayısal performans sonuçlarına göre; yüksek dönme hızında ve düşük debilerde iki akışkan arasındaki basınç farkının yaklaşık %9,2 değerine, yüksek debilerde ise yaklaşık %7’lere düştüğü görülmüştür. Pompa, 5 L/dak debide 5000 dev/dak dönme hızında 88,33 mmHg basınç değerine ulaşmıştır. Bu noktadaki pompa hidrolik verimi ise %52,74 olarak belirlenmiştir.
Heart failure, which has an important place in heart diseases, is a health condition that human heart cannot pump enough blood for various reasons. Mechanical systems called ventricular assist devices (VADs) have been developed to assist individiuals with this disease. Left ventricular assist devices help blood to be pumped from the left ventricle to the aorta. In this study, the hydrodynamic performance of a mixed flow left ventricular heart assist pump was determined by the computational fluid dynamics (CFD) method. In the analysis, the working fluid was used a non-newtonian mixture of water and xanthan solution (by mass 0,06% xanthan gum) which has similar rheological properties to blood, was used as the working fluid. Performance curves of pressure, flow and efficiency of the pump were obtained at rotational speeds of 5000, 6000 and 7000 rpm. In order to compare the results, CFD analysis are repeated with a Newtonian fluid, water glycerin solution (by volume 40% glycerin and 60% water). According to the numerical performance results of the pump, it was seen that the pressure difference between two fluids at high rotational speed and low flow rates is 9,2% and high flow rate it is decreased to about 7%. The pump reached a pressure value of 88,33mmHg at a rotation spxeed of 5000 rpm at 5L/ min. At this working point, the pump hydraulic efficiency was determined as 52,74%.
URI: https://app.trdizin.gov.tr/makale/TXpVek9EWXlNZz09
https://hdl.handle.net/20.500.13091/1204
ISSN: 2564-6605
2564-6605
Appears in Collections:Mühendislik ve Doğa Bilimleri Fakültesi Koleksiyonu
TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collections

Files in This Item:
File SizeFormat 
a8f59da5-67a2-46b3-b033-77a87391f24b.pdf599.42 kBAdobe PDFView/Open