Title: | Numerical investigation of the parameters influencing the behavior of dapped end prefabricated concrete purlins with and without CFRP strengthening | Authors: | Özkılıç, Yasin Onuralp Yazman, Şakir Aksoylu, Ceyhun Arslan, Musa Hakan Gemi, Lokman |
Keywords: | Concrete CFRP Hashin failure ABAQUS Prefabricated concrete purlins Fiber orientations Thinned end Dapped end |
Issue Date: | 2021 | Publisher: | ELSEVIER SCI LTD | Abstract: | Dapped end prefabricated concrete purlins (PCPs) suffer from shear damages due to coating, snow, wind load and also their dead loads. In this present study, a series of numerical modelling is performed with the aid of finite element program ABAQUS in order to investigate this behavior of PCPs through parametric study. In addition to the mechanical properties of the PCPs, the strengthening of the PCPs with the help of carbon fiber reinforced polymers (CFRP) is considered as a parameter in the models. Pursuant to this aim, longitudinal steel reinforcement ratio, shear friction reinforcement ratio, bending reinforcement ratio, suspension reinforcement ratio, concrete and steel mechanical properties, pre-stressing level, CFRP ply orientation, the number of CFRP plies and material properties of CFRP composite were selected as the parameters. First of all, numerical models were verified using experimental test data of three PCP test specimens and five CFRP coupon tests. Later, a total of 50 different numerical models was created to investigate the behavior of PCPs thoroughly. Vertical load- displacements curves are compared and explained in detail. The result of the parametric study revealed that the effects of the parameters related to reinforced concrete except longitudinal reinforcement and material properties of concrete are very limited when compared to the effects of the parameters related to CFRP. The effect of FRP ply orientation is the most effective parameter that increases significantly the shear capacity of PCPs. More importantly is the general FRP layout is proposed to delay or prevent shear cracks for the beams and the proposed layout is proved through numerical analyses. [+/- 45 degrees] fiber orientation is recommended to use to prevent shear damage. (C) 2020 Elsevier Ltd. All rights reserved. | URI: | https://doi.org/10.1016/j.conbuildmat.2020.122173 https://hdl.handle.net/20.500.13091/1141 |
ISSN: | 0950-0618 1879-0526 |
Appears in Collections: | Mühendislik ve Doğa Bilimleri Fakültesi Koleksiyonu Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collections WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collections |
Files in This Item:
File | Size | Format | |
---|---|---|---|
1-s2.0-S0950061820341763-main.pdf Until 2030-01-01 | 7.97 MB | Adobe PDF | View/Open Request a copy |
CORE Recommender
SCOPUSTM
Citations
17
checked on Mar 25, 2023
WEB OF SCIENCETM
Citations
40
checked on Jan 30, 2023
Page view(s)
74
checked on Mar 27, 2023
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.