Fast Evaluation of Unhealthy and Healthy Neonates Using Hyperspectral Features on 700-850 Nm Wavelengths, Roi Extraction, and 3d-Cnn

No Thumbnail Available

Date

2022

Authors

Cihan, Mücahit
Ceylan, Murat

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier Masson s.r.l.

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 10%
Influence
Average
Popularity
Top 10%

Research Projects

Journal Issue

Abstract

Objectives: Hyperspectral imaging (HSI) has great potential in detecting the health conditions of neonates as it provides diagnostic information about the tissue by avoiding tissue biopsy. HSI gives more features than thermal imaging, which can obtain images in a single wavelength, as it can obtain images in a large number of wavelengths. The data obtained with hyperspectral sensors are 3-dimensional data called hypercube including first two-dimensional spatial information and third-dimensional spectral information. Material and methods: In this study, hyperspectral data were obtained from 19 different neonates in the Neonatal Intensive Care Unit (NICU) of Selcuk University, Medical Faculty. There are 16 hypercubes from 16 unhealthy neonates, 16 hypercubes from 3 healthy neonates in a period of three months, and 32 hypercubes in total are available. For the training of 3D-CNN model, data augmentation methods, such as rotation, height shifting, width shifting, and shearing were applied to hyperspectral data. A number of 32 hypercubes taken from neonates in NICU were augmented to 160 hypercubes. Spectral signatures were examined and 51 bands in the range of 700-850 nm with distinctive features were used for the classification. The spectral dimension was reduced by applying Principal Component Analysis (PCA) to all hypercubes. In addition, it is aimed to obtain both spectral and spatial features with the 3D-CNN. For increasing the classification efficiency, ROI extraction was made and four datasets were created in different spatial dimensions. These datasets contain 160, 640, 1440, and 5760 hypercubes, respectively. Results: The best result was achieved by using 5760 hypercubes of 25x25x51. As a result of the classification of the hypercubes, accuracy 98.00%, sensitivity 97.22%, and specificity 98.78% were obtained. It was determined how many PCs used to achieve the best result. Further, the proposed 3D-CNN model is compared to 2D-CNN model to evaluate the performance of the study. Conclusion: It was aimed to evaluate the health status of neonates fastly by using HSI and 3D-CNN for the first time. The obtained results are an indication that HSI and 3D-CNN are very effective for the evaluation of unhealthy and healthy neonates. © 2021 AGBM

Description

Keywords

3D convolutional neural network, Classification, Deep learning, Hyperspectral imaging, Neonates, ROI extraction, Spectral-spatial features

Turkish CoHE Thesis Center URL

Fields of Science

0103 physical sciences, 0202 electrical engineering, electronic engineering, information engineering, 02 engineering and technology, 01 natural sciences

Citation

WoS Q

Q2

Scopus Q

Q1
OpenCitations Logo
OpenCitations Citation Count
6

Source

IRBM

Volume

43

Issue

Start Page

362

End Page

371
PlumX Metrics
Citations

CrossRef : 9

Scopus : 9

Captures

Mendeley Readers : 16

SCOPUS™ Citations

9

checked on Feb 04, 2026

Web of Science™ Citations

9

checked on Feb 04, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
1.31059982

Sustainable Development Goals

SDG data is not available