Bending Performance of Dapped-End Beams Having Web Opening: Experimental and Numerical Investigation

dc.contributor.author Aksoylu, Ceyhun
dc.contributor.author Özkiliç, Yasin Onuralp
dc.contributor.author Celedir, Emrullah
dc.contributor.author Arslan, Musa Hakan
dc.date.accessioned 2023-05-31T20:19:31Z
dc.date.available 2023-05-31T20:19:31Z
dc.date.issued 2023
dc.description.abstract Reinforced concrete dapped-end (purlin) beams are frequently used in prefabricated industrial structures. The main task of these beams is to safely carry the loads on the roof. Considering the number of these purlin beams in industrial buildings, it is extremely important for manufacturers to product these beams with less concrete without reducing the load carrying capacity. Since these purlin beams are under the effect of bending and shear forces, controlled creating openings in beam span can have significant economic benefits for the manufacturer. Therefore especially economic design perspective, it is so crucial to determine the amount of openings that will not cause a significant change in the bending behavior. In this study, the behavior of dapped-end purlins with openings was experimentally and numerically investigated. In the experimental step, seven purlin beams having different opening configurations were tested under four-point loading to investigate the openings effects on beam structural behavior. In this step opening length to total length varying between 0.075 and 0.325 was selected as a main parameter. After test, the numerical models were created and verified using experimental findings. After this step, in the parametric study part of the paper, the effects of shear span, depth of the opening and length of opening and different opening configurations (such as segmentation) which were not tested in experiments, were examined. The experimental outcomes revealed that increases in the opening did not provide a significant effect on the load capacity. This can be explained by the fact that the openings are in the bending region. The numerical findings showed that increasing shear span to depth ratio (av/d) ratio did not change rigidity but decreased the load capacity. However, no effect was observed on the opening height provided that it is at least as far away from the upper and lower longitudinal reinforcements bars as the concrete-cover margin. On the other hand, increasing opening/purlin length (especially higher than 0.375) reduces the capacity. However, segmented openings (multiple openings instead of single whole openings) did not reduce capacity even if total opening/ purlin length was 0.525. en_US
dc.description.sponsorship Konya Technical University Research Projects Coordination Unit [211004018] en_US
dc.description.sponsorship Acknowledgements This study was supported by Konya Technical University Research Projects Coordination Unit (Project Number: 211004018) .Authors also would like to thank Yard?mc? Prefabricated Building Components Inc.for helping producing purlins. en_US
dc.identifier.doi 10.1016/j.istruc.2022.12.110
dc.identifier.issn 2352-0124
dc.identifier.scopus 2-s2.0-85149727687
dc.identifier.uri https://doi.org/10.1016/j.istruc.2022.12.110
dc.identifier.uri https://hdl.handle.net/20.500.13091/4223
dc.language.iso en en_US
dc.publisher Elsevier Science Inc en_US
dc.relation.ispartof Structures en_US
dc.rights info:eu-repo/semantics/closedAccess en_US
dc.subject Bending en_US
dc.subject Beam en_US
dc.subject Purlin en_US
dc.subject Dapped-end beam en_US
dc.subject Opening en_US
dc.subject Experimental analysis en_US
dc.subject Numerical analysis en_US
dc.subject Reinforced-Concrete Beams en_US
dc.subject Rc Beams en_US
dc.subject Flexural Behavior en_US
dc.subject Seismic Performance en_US
dc.subject Strength en_US
dc.subject Design en_US
dc.subject Steel en_US
dc.title Bending Performance of Dapped-End Beams Having Web Opening: Experimental and Numerical Investigation en_US
dc.type Article en_US
dspace.entity.type Publication
gdc.author.id Özkiliç, Yasin Onuralp/0000-0001-9354-4784
gdc.author.id AKSOYLU, Ceyhun/0000-0002-1574-4251
gdc.author.institutional
gdc.author.scopusid 57193686945
gdc.author.scopusid 57203961386
gdc.author.scopusid 58136968600
gdc.author.scopusid 11940766700
gdc.author.wosid Özkiliç, Yasin Onuralp/AAA-9279-2019
gdc.author.wosid AKSOYLU, Ceyhun/AAQ-1447-2020
gdc.bip.impulseclass C4
gdc.bip.influenceclass C5
gdc.bip.popularityclass C4
gdc.coar.access metadata only access
gdc.coar.type text::journal::journal article
gdc.description.department KTÜN en_US
gdc.description.departmenttemp [Aksoylu, Ceyhun; Celedir, Emrullah; Arslan, Musa Hakan] Konya Tech Univ, Fac Engn & Nat Sci, Dept Civil Engn, TR-42130 Konya, Turkiye; [Ozkilic, Yasin Onuralp] Necmettin Erbakan Univ, Fac Engn, Dept Civil Engn, TR-42000 Konya, Turkiye en_US
gdc.description.endpage 753 en_US
gdc.description.publicationcategory Makale - Uluslararasi Hakemli Dergi - Kurum Ögretim Elemani en_US
gdc.description.scopusquality Q1
gdc.description.startpage 736 en_US
gdc.description.volume 48 en_US
gdc.description.wosquality Q1
gdc.identifier.openalex W4313539305
gdc.identifier.wos WOS:000920824700001
gdc.index.type WoS
gdc.index.type Scopus
gdc.oaire.diamondjournal false
gdc.oaire.impulse 9.0
gdc.oaire.influence 2.913416E-9
gdc.oaire.isgreen false
gdc.oaire.keywords Numerical Analysis
gdc.oaire.keywords Bending
gdc.oaire.keywords Dapped-end Beam
gdc.oaire.keywords Beam
gdc.oaire.keywords Experimental Analysis
gdc.oaire.keywords Purlin
gdc.oaire.keywords Opening
gdc.oaire.popularity 8.174494E-9
gdc.oaire.publicfunded false
gdc.oaire.sciencefields 0211 other engineering and technologies
gdc.oaire.sciencefields 02 engineering and technology
gdc.oaire.sciencefields 0201 civil engineering
gdc.openalex.collaboration National
gdc.openalex.fwci 2.14208268
gdc.openalex.normalizedpercentile 0.82
gdc.opencitations.count 6
gdc.plumx.crossrefcites 8
gdc.plumx.mendeley 8
gdc.plumx.scopuscites 11
gdc.scopus.citedcount 10
gdc.virtual.author Aksoylu, Ceyhun
gdc.virtual.author Arslan, Musa Hakan
gdc.wos.citedcount 8
relation.isAuthorOfPublication 4b513eb3-773f-45ba-a4bd-ac58f11c9614
relation.isAuthorOfPublication 8f79018a-d4d5-4699-981e-4b84dc964c82
relation.isAuthorOfPublication.latestForDiscovery 4b513eb3-773f-45ba-a4bd-ac58f11c9614

Files

Original bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
1-s2.0-S235201242201298X-main.pdf
Size:
27.45 MB
Format:
Adobe Portable Document Format