Behavior of Cfrp-Strengthened Rc Beams With Circular Web Openings in Shear Zones: Numerical Study
No Thumbnail Available
Date
2022
Authors
Journal Title
Journal ISSN
Volume Title
Publisher
Elsevier Science Inc
Open Access Color
Green Open Access
No
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
In practice, especially the basement floor beams are drilled and damaged by the users. In some cases, this damage to the beams can be significant for the load-bearing element and the whole structure. In this study, the behavior of reinforced concrete beams with circular openings and the failure types resulting from strengthening these beams with CFRP are parametrically investigated. The diameter of the opening/beam height ratio (D/H), con-crete compressive strength, stirrup spacing, the position of the opening to the beam support, the type of CFRP application, CFRP ply orientation, and the number of CFRP layers were selected as parameters. Numerical models were verified using 9 specimens having different circular openings with/without CFRP strengthening and the analyses of 95 numerical models with the selected parameters were carried out utilizing the finite element program, ABAQUS. The ultimate load capacity, ductility, stiffness, energy dissipation capacity and failure modes of the beams were determined. As a result of the study, it was observed that there was no significant loss in ductility for the beams with D/H < 0.3 and the number of CFRP layer and type of application did not have a significant effect on D/H < 0.44. However, for the beams with D/H > 0.64, the CFRP application that completely surrounds openings should be preferred instead of partial CFRP strengthening. In addition, the concrete strength is an effective parameter for the beams with D/H < 0.44. The effect of the stirrup spacings in the beam on the ductile behavior was also limited with the increase in the hole diameter. The number of CFRP layers should theoretically be 4 for an effective strengthening in beams with D/H > 0.44. Finally, U wrapping is recommended instead of using full wrapping. It has been seen that the location and diameter of the hole are very important parameters in the failure type of the beam.
Description
Keywords
CFRP, Circular opening, Failure modes, Reinforced concrete beam, Shear damage, Reinforced-Concrete Beams, Tubular T-Joints, Flexural Behavior, R/C Beams, Deep Beams, Performance, Design, Tests
Turkish CoHE Thesis Center URL
Fields of Science
02 engineering and technology, 0201 civil engineering
Citation
WoS Q
Q1
Scopus Q
Q1

OpenCitations Citation Count
50
Source
Structures
Volume
41
Issue
Start Page
1369
End Page
1389
PlumX Metrics
Citations
CrossRef : 53
Scopus : 79
Captures
Mendeley Readers : 37
SCOPUS™ Citations
75
checked on Feb 03, 2026
Web of Science™ Citations
70
checked on Feb 03, 2026
Google Scholar™

OpenAlex FWCI
7.98685237
Sustainable Development Goals
7
AFFORDABLE AND CLEAN ENERGY

9
INDUSTRY, INNOVATION AND INFRASTRUCTURE