Simulation Model Assessment of a Sound Insulating Double Façade System With Openings for Natural Ventilation Under Guidance of Laboratory Measurements

dc.contributor.author Çakır, Onurcan
dc.contributor.author Lechleitner, Josef
dc.contributor.author Mahdavi, Ardeshir
dc.date.accessioned 2022-08-15T17:34:52Z
dc.date.available 2022-08-15T17:34:52Z
dc.date.issued 2012
dc.description 10 en_US
dc.description iconarch:S1 en_US
dc.description.abstract Noise control and natural ventilation are two main building physics issues which have contradictory principles. While natural ventilation needs openings on the façade in order to let fresh air in, the desired acoustic insulation is provided with minimum openings or without any opening on the wall. This paper presents a comparison between the simulation model results and laboratory measurements of a double façade system which is proposed in order to minimize outdoor noise coming through façade openings in naturally ventilated buildings. The double façade with twenty five openable equal-size particleboard panels on each side was constructed as a full scale model in the laboratory and the same setup was modeled in a computer simulation program. Different parts from these two parallel walls were taken out and the effect of the distance between these openings on the sound reduction value of the system has been analyzed. After the measurements; materials, their sound absorption coefficients and the reverberation times of two rooms were calibrated in the simulation program accordingly and simulations were run in order to check if it would be possible to continue this research only with computer models. The results are compared and differences between the simulation and laboratory measurements are stated in this paper. en_US
dc.identifier.uri https://iconarch.ktun.edu.tr/index.php/iconarch/article/view/10/5
dc.identifier.uri https://iconarch.ktun.edu.tr/index.php/iconarch/article/view/10
dc.identifier.uri https://hdl.handle.net/20.500.13091/2565
dc.language.iso en en_US
dc.publisher Konya Technical University Faculty of Architecture and Design en_US
dc.relation.ispartof ICONARCH International Congress of Architecture and Planning; 2012: ICONARCH I - ARCHITECTURE AND TECHNOLOGY en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.subject Noise control en_US
dc.subject natural ventilation en_US
dc.subject acoustics en_US
dc.subject sound insulation en_US
dc.subject simulation en_US
dc.title Simulation Model Assessment of a Sound Insulating Double Façade System With Openings for Natural Ventilation Under Guidance of Laboratory Measurements en_US
dc.type Conference Object en_US
dspace.entity.type Publication
gdc.coar.access open access
gdc.coar.type text::conference output
gdc.description.endpage 42 en_US
gdc.description.publicationcategory Konferans Öğesi - Uluslararası - Başka Kurum Yazarı en_US
gdc.description.scopusquality N/A
gdc.description.startpage 35 en_US