Geometric Optimization of a Blood Pump Impeller Using the Taguchi Method: Cfd Analysis and Experimental Evaluation

No Thumbnail Available

Date

2025

Authors

Yapici, Rafet
Incebay, Omer

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Open Access Color

GOLD

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Average
Influence
Average
Popularity
Top 10%

Research Projects

Journal Issue

Abstract

Rotodynamic Left Ventricular Assist Devices (LVADs) are critical in managing severe heart failure by providing mechanical circulatory support. Improving these blood pumps'efficiency is crucial for both lowering the device's energy consumption and enhancing patient comfort. In this study, the efficiency of a reference centrifugal blood pump was improved through geometric optimization and validated using computational fluid dynamics (CFD) simulations and experiments. The number of blades, inlet width, outlet width, inlet angle, and outlet angle are among the important impeller parameters that were optimized at three different levels. The orthogonal array of the Taguchi design method was used to reduce the 243 possible configurations from the full-factorial experimental design to 27 trial tests. Analysis of Variance (ANOVA) was used to determine the optimal geometric parameters, which led to maximum efficiency after S/N ratios were analyzed using MINITAB-18 software. The performance of the optimized pump was evaluated via CFD at 3300, 3150, and 3450 pump rotation speeds, resulting in a 21% increase in hydraulic efficiency at the design point (5 L/min, 3300 rpm, and 128.515 mm-Hg). Furthermore, experimental results demonstrated reduced power consumption for the optimized pump compared to the reference pump. This study highlights the potential of geometric optimization in advancing the performance of rotodynamic LVADs.

Description

Keywords

Cfd, Optimization, Taguchi Method, Blood Pump, Rotodynamic Lvad, Anova, Optimization, ANOVA, Medical technology, Taguchi method, R855-855.5, CFD, Blood pump, Rotodynamic LVAD

Turkish CoHE Thesis Center URL

Fields of Science

Citation

WoS Q

N/A

Scopus Q

Q2
OpenCitations Logo
OpenCitations Citation Count
N/A

Source

Medicine in Novel Technology and Devices

Volume

26

Issue

Start Page

100364

End Page

PlumX Metrics
Citations

CrossRef : 1

Scopus : 2

Captures

Mendeley Readers : 13

SCOPUS™ Citations

2

checked on Feb 03, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
3.98572362

Sustainable Development Goals

SDG data could not be loaded because of an error. Please refresh the page or try again later.