Numerical Investigation of the Parameters Influencing the Behavior of Dapped End Prefabricated Concrete Purlins With and Without Cfrp Strengthening

Loading...
Thumbnail Image

Date

2021

Authors

Journal Title

Journal ISSN

Volume Title

Publisher

ELSEVIER SCI LTD

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Top 1%
Influence
Top 10%
Popularity
Top 1%

Research Projects

Journal Issue

Abstract

Dapped end prefabricated concrete purlins (PCPs) suffer from shear damages due to coating, snow, wind load and also their dead loads. In this present study, a series of numerical modelling is performed with the aid of finite element program ABAQUS in order to investigate this behavior of PCPs through parametric study. In addition to the mechanical properties of the PCPs, the strengthening of the PCPs with the help of carbon fiber reinforced polymers (CFRP) is considered as a parameter in the models. Pursuant to this aim, longitudinal steel reinforcement ratio, shear friction reinforcement ratio, bending reinforcement ratio, suspension reinforcement ratio, concrete and steel mechanical properties, pre-stressing level, CFRP ply orientation, the number of CFRP plies and material properties of CFRP composite were selected as the parameters. First of all, numerical models were verified using experimental test data of three PCP test specimens and five CFRP coupon tests. Later, a total of 50 different numerical models was created to investigate the behavior of PCPs thoroughly. Vertical load- displacements curves are compared and explained in detail. The result of the parametric study revealed that the effects of the parameters related to reinforced concrete except longitudinal reinforcement and material properties of concrete are very limited when compared to the effects of the parameters related to CFRP. The effect of FRP ply orientation is the most effective parameter that increases significantly the shear capacity of PCPs. More importantly is the general FRP layout is proposed to delay or prevent shear cracks for the beams and the proposed layout is proved through numerical analyses. [+/- 45 degrees] fiber orientation is recommended to use to prevent shear damage. (C) 2020 Elsevier Ltd. All rights reserved.

Description

Keywords

Concrete, CFRP, Hashin failure, ABAQUS, Prefabricated concrete purlins, Fiber orientations, Thinned end, Dapped end

Turkish CoHE Thesis Center URL

Fields of Science

02 engineering and technology, 0210 nano-technology, 0201 civil engineering

Citation

WoS Q

Q1

Scopus Q

Q1
OpenCitations Logo
OpenCitations Citation Count
64

Source

CONSTRUCTION AND BUILDING MATERIALS

Volume

275

Issue

Start Page

122173

End Page

PlumX Metrics
Citations

CrossRef : 63

Scopus : 91

Captures

Mendeley Readers : 56

SCOPUS™ Citations

91

checked on Feb 04, 2026

Web of Science™ Citations

85

checked on Feb 04, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
9.18181973

Sustainable Development Goals