Copper (Cu) solvent extraction (SX) from sulphate leach solution was investigated using Robust design (Taguchi design). The effect of some parameters, including pH (1.25-5), phase ratio (O/A: 1/3-2/1), concentration of the extractant (2.5-10% v/v) and extraction duration (5-20 min) were examined. In the investigation of SX, the ranges and experimental parameters chosen are as follows: pH, 3.75; concentration of the extractant, 7.5% v/v; Aqueous /Organic ratio, 3/1 and extraction duration, 10 min. Under these conditions, Cu extraction of 94.62% was achieved. Variance analysis technique (ANOVA) suggested that, the most effective parameter was pH and the less effective parameter was the aqueous /organic ratio. Using of 1.5 M H2SO4 allowed for a stripping efficiency of 98% Cu from the organic phase.
Açıklama
Anahtar kelimeler
Lix 984N, Solvent Extraction, Copper, Extraction Efficiency, Robust Design Method
Bilim Dalları
0205 materials engineering, 02 engineering and technology
Alıntı
WoS Q
Scopus Q
Cilt
78
Sayı
1
Başlangıç Sayfası
Bitiş Sayfası