Abstract

Corrosion is one of the most important factor to achieve in completing the service life of reinforced concrete structures also cause significant losses in energy damping capacities of structures. In this study, the reinforced concrete column designed in ½ geometrical scale was subjected to accelerated corrosion test for 26.5 days under 1 ampere constant current. As a result of the experiment, weight loss and strength reductions was obtained. Loss of strength in reinforcement due to corrosion damage was obtained with experimental procedure. Loss of cross section and reduction of compressive strength of concrete were obtained with empirical formulas in the literature. Thanks to this data, 3 different scenarios applied on a sample building in Hatay province. Static pushover analyzes of the sample building designed in accordance with the regulations were carried out with Sap 2000 program under the specified corrosion scenarios. The load-displacement curves obtained by the scenarios are compared with the curves of the reference building. As a result of the comparisons, it was observed that corrosion damage caused significant loss in horizontal load carrying capacity of the building. The corrosion scenarios show that corrosion in columns or beams changes collapse modes of the structure.

Description

Keywords

Corrosion, Static Pushover Analysis, Accelerated Corrosion, Reinforced Concrete Column

Turkish CoHE Thesis Center URL

Fields of Science

Citation

WoS Q

N/A

Scopus Q

Q2

Source

Natural and Engineering Sciences

Volume

4

Issue

1

Start Page

11

End Page

20
Page Views

3

checked on Feb 03, 2026

Downloads

13

checked on Feb 03, 2026

Google Scholar Logo
Google Scholar™

Sustainable Development Goals

SDG data could not be loaded because of an error. Please refresh the page or try again later.