Profile URL: https://hdl.handle.net/20.500.13091/11983
Job Title:Arş. Gör. Uzm.
Email Address:aarpinar@ktun.edu.tr
Main Affiliation:02.10. Department of Mechanical Engineering
Status: Current Staff
ORCID:
0000-0001-8748-6194
0000-0001-8748-6194Google Scholar:
WYVjcpQAAAAJ
WYVjcpQAAAAJName Variants:
Arpinar, Asli Arpinar, A.
Scholarly Output Search Results
Now showing 1 - 4 of 4
Article PVT-Evaporatörlü ve Değişken Devirli Kompresörlü Bütünleşik Isı Pompası Sisteminin Performansının Araştırılması(2024) Ersoy, H. Kursad; Arpınar, AslıBu çalışmada bir PVT (fotovoltaik termal) ve değişken devirli ısı pompası bütün- leşik sisteminin enerjetik analizi yapılmıştır. Tasarlanan sistem için matematiksel model kurulmuş ve sistemin çözüm algoritmaları EES’de (Engineering Equation Solver) oluşturularak PVT alanı, ışınım, çevre sıcaklığı ve kompresör devir sayı- sının sistem performansına etkisi araştırılmıştır. Değişken devirli kompresörlü PVT’li ve PVT’siz (hava kaynaklı) bir ısı pompası sisteminin Antalya’da kurulması durumunda ısıtma sezonu için termal performansı karşılaştırılmıştır. Elde edilen sonuçlara göre, PVT panel alanı veya ışınım miktarının artmasıyla ısıt- ma performans katsayısının (COPIP), kondenser ve kompresör gücü artışına bağlı olarak önce hızla artmakta, panel alanının belirli bir değerinden sonra COPIP hemen hemen sabit kalırken, ışınım miktarının belirli bir değerinden sonra ise COPIP değeri hafifçe de olsa azalmaktadır. Çevre sıcaklığı artışı ile ise kompresör tüketim gücünün azaldığı ve COPIP değerinin artığı tespit edildi. PVT panel alanı 1.65x9 m2, ışınım miktarı 500 W/m2, çevre sıcaklığı 0 °C ve kondenser sıcaklığı 55 °C iken PVT’siz ısı pompasının PVT’li ısı pompasına göre kompresör tüketim gücünün %31.94 daha yüksek, COPIP değerinin %27.87 daha düşük olduğu bulundu. Antalya ili ısıtma se- zonunda PVT’siz sistemin ortalama COPIP değeri 2.724 bulunurken PVT’li sistemin ortalama COPIP değeri 3.665 yani %34.55 daha yüksek bulunmuştur.Article Isı Pompası için Pvt-evaporatörün Isıtma Sezonunda Performans Karakteristiğinin Araştırılması(TMMOB Makina Mühendisleri Odası, 2024) Arpınar Aslı; Ersoy Halil Kürşad; Ersoy, H. Kursad; Arpınar, AslıIsıtma (kış) sezonu için ısı pompası evaporatörü olarak görev yapacak R404A soğutucu akışkanlı fotovoltaik termal panelin (PVT) performans analizi gerçekleştirilmiştir. PVT panelin matematiksel modeline ilişkin çözüm algoritmaları EES’de (Engineering Equation Solver) oluşturularak ışınım miktarı, PVT kolektör alanı ve çevre sıcaklığı parametrelerinin PVT panellerden üretilen elektrik gücüne, PVT’nin elektriksel verimine etkileri incelenmiştir. Türkiye’nin Konya ili örnek olarak seçilmiş, meteorolojik veriler kullanılarak ısıtma sezonu için PVT-Evaporatörün performans karakteristiği araştırılmıştır. Elde edilen sonuçlara göre, ışınım miktarı ve panel alanının artması, çevre sıcaklığının ise azalması durumunda üretilen elektrik gücünün lineer olarak arttığı belirlenmiştir. PVT-Evaporatörün soğutucu akışkanla soğutulması durumunda elektriksel veriminin arttığı tespit edilmiştir. Işınım 1000 W/m2, çevre sıcaklığı 0 °C iken panel 1 °C soğutulduğunda elektriksel verim %0,24 artmaktadır. 1,65x9 m2 panel alanına sahip PVT’nin Konya’da kurulması durumunda ısıtma sezonunda PVT’den gün içinde ve ortalama 2,88 kW ısıl güç, 1,02 kW elektriksel güç elde edilebileceği ve PVT’nin ortalama elektriksel veriminin %23,19 olacağı tespit edilmiştir. Işınım miktarının yüksek olduğu 10.00-14.00 saatleri arasında elektriksel ve ısıl güç üretimi artmış, elektriksel verim ise hücre ve çevre sıcaklığı arttığı için düşmüştür.Article Isı Pompası için PVT-Evaporatörün Isıtma Sezonunda Performans Karakteristiğinin Araştırılması(2024) Ersoy, H. Kursad; Arpınar, AslıA performance analysis of a photovoltaic thermal panel (PVT) using R404A refrigerant as the heat pump evaporator for the heating (winter) season was conducted. The solution algorithms related to the mathematical model of the PVT panel were created in EES (En- gineering Equation Solver), and the effects of irradiation amount, PVT collector area, and ambient temperature parameters on the electrical power generated by the PVT panels and the electrical efficiency of the PVT were investigated. Konya, a city in Turkey, was cho- sen as an example, and using meteorological data, the performance characteristics of the PVT-Evaporator for the heating season were investigated. The results indicated that the electrical power produced increased linearly with the in- crease in radiation amount and panel area, and with the decrease in ambient temperature. It was determined that cooling the PVT-Evaporator with refrigerant enhanced its electrical efficiency. When the radiation is 1000 W/m² and the ambient temperature is 0°C, the elec - trical efficiency increases by 0.24% when the panel is cooled by 1°C. If a PVT with a panel area of 1.65x9 m² is installed in Konya, it is determined that during the heating season, an average of 2.88 kW thermal power and 1.02 kW electrical power can be obtained from the PVT daily, with an average electrical efficiency of 23.19%. During the hours of 10:00-14:00, when radiation is high, the production of electrical and thermal power increased, while the electrical efficiency decreased due to the rise in cell and ambient temperatures.Master Thesis Fotovoltaik Termal (pvt) Panel ve Hava Kaynaklı Isı Pompası Bütünleşik Sisteminin Termodinamik Analizi(Konya Teknik Üniversitesi, 2024) Arpınar, Aslı; Ersoy, Hali̇l KürşadIsıtma-soğutma ihtiyacını karşılamak ve elektrik üretmek amacıyla kullanılabilecek bir PVT (fotovoltaik termal) ve ısı pompası bütünleşik sisteminin enerjetik analizi yapılmıştır. Öngörülen sistemde sabit ve/veya değişken devirde çalışabilen hermetik scroll kompresörlü hava kaynaklı R404A soğutucu akışkanlı bir ısı pompasının kullanıldığı düşünülmüş ve sistemin çözüm algoritmaları EES'ye (Engineering Equation Solver) aktarılarak parametrik analizler yapılmıştır. Elde edilen sonuçlara göre, ışınım miktarı ve panel alanının artması, çevre sıcaklığının ise azalması durumunda üretilen elektrik gücünün lineer olarak arttığı belirlenmiştir. PVT-Evaporatör entegrasyonu yapılarak panelin soğutucu akışkanla soğutulması durumunda elektriksel veriminin arttığı tespit edilmiştir. Sabit devirde çalışan kompresörlü ve PVT'li bir bütünleşik sistemde ışınım veya panel alanının artması veya çevre sıcaklığının azalması durumunda kondenser sıcaklığı ve kompresör gücü düşmekte ve COPIP yükselmektedir. Değişken devirde çalışan kompresörlü ve PVT'li bir bütünleşik sistemde ışınım ve alan artışı ile kompresör devir sayısı artmakta COPIP ise kompresörde tüketilen güç ve kondenser kapasitesindeki artışa bağlı olarak ilk başta hızla artmakta belirli bir değerden sonra ise artış oranı yavaşlamaktadır. Değişken devirli kompresörlü sistemde çevre sıcaklığı 0 oC ve kondenser sıcaklığı 55 oC iken, PVT'li ısı pompasının ısıtma performans katsayısı, PVT'siz sisteme göre %27,87 daha yüksektir. Sabit veya değişken devirde çalışan kompresörlü ve 1,65 x9 m2 panel alanlı bütünleşik bir sistemin Antalya iline kurulması durumunda öğle saatlerinde üretilen elektriğin, ısıtma sezonu boyunca (Ekim-Mart) kompresör tüketim gücünü karşılayacağı belirlenmiştir. Ancak, sabit devirli bütünleşik sistemde kondenser sıcaklığının öğle saatlerinde 25 oC'ye kadar düşeceği, değişken devirli sistemde ise devir sayısı ayarlanarak kondenser sıcaklığının 55 oC'de sabit tutulabileceği ve ısıtmanın daha konforlu yapılabileceği tespit edilmiştir. Antalya ili için ısıtma sezonunda değişken devirli kompresörlü bütünleşik sistemin COPIP'unun PVT'siz sisteme göre ortalama %34,55 daha yüksek olduğu belirlenmiştir. Antalya ili için soğutma sezonunda (Nisan-Eylül), kondenser sıcaklığı 45 oC iken, sabit devirli bütünleşik sistemde 09.45-14.45 saatleri arasında, değişken devirli bütünleşik sistemde ise 08.45-16.45 saatleri arasında elektrik üretimi kompresör tüketim gücünü karşılayabileceği tespit edilmiştir.
No research topics data found.
Sustainable Development Goals
7AFFORDABLE AND CLEAN ENERGY
4
Research Products

This researcher does not have a Scopus ID.

This researcher does not have a WoS ID.
No records found in other affiliations.
| Journal | Count |
|---|---|
| Tesisat Mühendisliği | 3 |
Current Page: 1 / 1

Scholarly Output
4
Articles
3
Views / Downloads
2/21
Supervised MSc Theses
1
Supervised PhD Theses
0
WoS Citation Count
0
Scopus Citation Count
0
Patents
0
Projects
0
WoS Citations per Publication
0.00
Scopus Citations per Publication
0.00
Open Access Source
3
Supervised Theses
1
Scopus Quartile Distribution
Quartile distribution chart data is not available
Competency Cloud

