Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/950
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKunt, Fatma-
dc.contributor.authorAyturan, Zeynep Cansu-
dc.contributor.authorYümün, Feray-
dc.contributor.authorKaragönen, İlknur-
dc.contributor.authorSemerci, Mümin-
dc.contributor.authorAkgün, Mehmet-
dc.date.accessioned2021-12-13T10:32:12Z-
dc.date.available2021-12-13T10:32:12Z-
dc.date.issued2021-
dc.identifier.issn0167-6369-
dc.identifier.issn1573-2959-
dc.identifier.urihttps://doi.org/10.1007/s10661-021-09428-w-
dc.identifier.urihttps://hdl.handle.net/20.500.13091/950-
dc.description.abstractAir pollution has negative effects on human health, visibility, materials, plants, and animal health. Particulate matters are one of the most important air pollutants that may create a risk for human health. Especially particulate matters, which are composed of heavy metals and cancer-causing chemicals such as PAH, dioxin, furan, can cause serious reactions in the respiratory tract. Heavy metals are so important because of their capability of accumulation in human tissues. Almost 0.01-3% of heavy metal content may be found in particulate matter. Coarse particulate matters (PM10) which have smaller diameters than 10 microns may enter from the respiratory system and reach the lungs. In this study, PM10 concentrations and heavy metal content (Lead, Nickel, Arsenic, Cadmium) of the samples were measured and evaluated concerning present regulations and limit values for different points in Konya Province, Turkey. The samples were taken at different seasons such as winter, summer, and spring for 16 days. According to the results of this study, in the winter season, PM10 concentration of the measurement point (Directorate Building) located at the settlement area was found the highest. In the summer season, PM10 concentration of the measurement point (Sille Junction) located at crossroads was found the highest. In spring season, maximum PM10 concentration was detected on the measurement point (KOS base station) located in the industrial area. Moreover, daily average nickel (Ni) concentration measured at KOS base station was found the highest and some other station located close to the industrial area and settlement areas were detected higher than average annual limit values in the winter period. Daily average lead (Pb) value was found at least 67% and maximum 98% higher at Sille and Besyol Junctions, but below the annual average limits. Daily average cadmium (Cd) value was mostly calculated in the Directorate Building winter measurement, but it did not exceed the limit value during the measurement periods. Daily average arsenic (As) values at Directorate Building and Karkent measurement points in the winter period were found higher than the annual average limit values. Only daily average nickel concentrations were detected higher than the annual average limits for the summer and spring period at the KOS base station measurement point.en_US
dc.description.sponsorshipMinistry of Environment and Urbanization, General Directorate of Environmental Impact Assessment Permitting and Inspection, Laboratory Measurement and Monitoring Departmenten_US
dc.description.sponsorshipThe laboratory analysis of this work was conducted at the Environmental Reference Laboratory affiliated with the Ministry of Environment and Urbanization. This work is funded by the Ministry of Environment and Urbanization, General Directorate of Environmental Impact Assessment Permitting and Inspection, Laboratory Measurement and Monitoring Department, Environmental Reference Laboratory.en_US
dc.language.isoenen_US
dc.publisherSPRINGERen_US
dc.relation.ispartofENVIRONMENTAL MONITORING AND ASSESSMENTen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectParticulate matteren_US
dc.subjectHeavy metalsen_US
dc.subjectAir pollutionen_US
dc.subjectLimit comparisonen_US
dc.subjectKonyaen_US
dc.titleMeasurement and evaluation of particulate matter and atmospheric heavy metal pollution in Konya Province, Turkeyen_US
dc.typeArticleen_US
dc.identifier.doi10.1007/s10661-021-09428-w-
dc.identifier.pmidPubMed: 34499227en_US
dc.identifier.scopus2-s2.0-85114671405en_US
dc.departmentFakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, Maden Mühendisliği Bölümüen_US
dc.authoridKunt, Fatma/0000-0003-2128-261X-
dc.identifier.volume193en_US
dc.identifier.issue10en_US
dc.identifier.wosWOS:000694853200001en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid34768491900-
dc.authorscopusid57204971317-
dc.authorscopusid57253879600-
dc.authorscopusid57254573500-
dc.authorscopusid57254459000-
dc.authorscopusid57110049400-
dc.identifier.scopusqualityQ2-
item.languageiso639-1en-
item.fulltextWith Fulltext-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.grantfulltextembargo_20300101-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
crisitem.author.dept02.06. Department of Environmental Engineering-
Appears in Collections:Mühendislik ve Doğa Bilimleri Fakültesi Koleksiyonu
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collections
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collections
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collections
Files in This Item:
File SizeFormat 
s10661-021-09428-w.pdf
  Until 2030-01-01
4.75 MBAdobe PDFView/Open    Request a copy
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

1
checked on Apr 20, 2024

WEB OF SCIENCETM
Citations

2
checked on Apr 20, 2024

Page view(s)

304
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.