Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/86
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAli, Ali Murthada-
dc.contributor.authorArslan, Musa Hakan-
dc.contributor.authorAltın, Mustafa-
dc.date.accessioned2021-12-13T10:19:44Z-
dc.date.available2021-12-13T10:19:44Z-
dc.date.issued2019-
dc.identifier.issn2528-9640-
dc.identifier.urihttps://doi.org/10.21324/dacd.458094-
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TXpnM01UZ3pNdz09-
dc.identifier.urihttps://hdl.handle.net/20.500.13091/86-
dc.description.abstractCam lifi taze beton karışımına eklenerek betonun mekanik özellikleri iyileştirilmektedir. Literatürde cam lif takviyeli betonun (CTB) mekanik özelliklerinin tespitine yönelik çok sayıda araştırma yapılmıştır. Beton içine cam lifi eklenerek özellikle betonun eğilme ve çekme dayanımında hatırı sayılır artışlar meydana gelmekte, bu şekilde üretilmiş olan betonlar daha ince kesitli oldukları için de uygulamada tercih edilmektedirler. Betonun içine eklenen cam lifinin betonun yangın performansına olumsuz bir etki yapıp yapmadığına yönelik kapsamlı bir araştırma olmadığı için bu çalışmada dört farklı (30,60, 90 ve 120 dk) yangın sürelerine tabi tutulmuş cam lif takviyesiz beton ile CTB elemanlarının yangın sonrasındaki mekanik özelliklerindeki değişiklikler incelenmiştir. Deneysel çalışma kapsamında Ø15/30 cm silindir ve 4x4x16 cm prizmadan oluşan toplam 300 adet numune üretilmiştir. Numunelerde kullanılan 0,5,10,15 ve 20 kg/m3 oranlarındaki cam elyaf takviyeli betonların değişik sürelerde yangın sonrasındaki basınç ve üç farklı çekme (yarma, tek noktadan eğilme ve iki noktadan eğilme) dayanımı üzerindeki etkisi farklı sürelerde yangına maruz bırakılan CTB elemanları üzerinden test edilmiştir. Yangın geçirmemiş numunelerde cam lifi basınç dayanımına bir katkıda bulunmazken çekme dayanımında önemli oranlarda katkısı olmuştur. 30 dakikalık yangın sonrasında CTB numunelerin tek ve çift noktadan eğilme deneylerinden elde edilen çekme dayanımlarında yangın öncesine göre bir artış görülmüştür. Daha uzun süreli yangınlarda (60, 90 ve 120 dk) ise bu oranda bir artış meydana gelmemiştir.en_US
dc.description.abstractThe mechanical properties of the concrete are improved by adding glass fiber to the fresh concrete mixture. Numerous studies have been carried out in the literature to determine the mechanical properties of glass fiber reinforced concrete (GRC). By adding glass fiber into the concrete, the bending and tensile strength of it increase considerable, and concretes produced in this way are preferred in practice to be thinner. Since there is no comprehensive investigation of the fire performance of the GRC used in practice, this study examined the changes in the mechanical properties of GRC elements subjected to four different (30, 60, 90 and 120 min) fire periods. In the scope of the experimental study, 300 samples including Ø15 / 30 cm cylinder and 4x4x16 cm prism were produced. The effect of glass fiber admixture of 0,5,10,15 and 20 kg / m3 on the compressive and different tensile strength of the concrete was tested on GRC elements exposed to fire for different periods of time. A significant contribution of glass fiber to the tensile strength for unburned samples has been observed, however glass fiber does not contribute to the compressive strength. After 30 minutes of fire, tensile strengths of single and double point bending tests of GRC samples increased. In the case of longer fires, there has not been an increase in this rate.en_US
dc.language.isotren_US
dc.relation.ispartofDoğal Afetler ve Çevre Dergisien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleCam Lif Takviyeli Betonun Yangın Dayanımlarının Çeşitli Parametreler Açısından İrdelenmesien_US
dc.title.alternativeEvaluation of Fire Resistance of Glass Fibre Concrete in Terms of Various Parametersen_US
dc.typeArticleen_US
dc.identifier.doi10.21324/dacd.458094-
dc.departmentMeslek Yüksekokulları, Teknik Bilimler Meslek Yüksekokulu, İnşaat Bölümüen_US
dc.identifier.volume5en_US
dc.identifier.issue2en_US
dc.identifier.startpage198en_US
dc.identifier.endpage213en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.trdizinid387183en_US
item.cerifentitytypePublications-
item.grantfulltextopen-
item.languageiso639-1tr-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeArticle-
item.fulltextWith Fulltext-
crisitem.author.dept02.02. Department of Civil Engineering-
crisitem.author.dept07. 07. Department of Construction Technology-
Appears in Collections:Teknik Bilimler Meslek Yüksekokulu Koleskiyonu
TR Dizin İndeksli Yayınlar Koleksiyonu / TR Dizin Indexed Publications Collections
Files in This Item:
File SizeFormat 
51dbc74d-4614-4119-9db9-6feaffa2b726.pdf2.04 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

156
checked on Apr 15, 2024

Download(s)

40
checked on Apr 15, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.