Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/40
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAkbal, Bahadır-
dc.date.accessioned2021-12-13T10:19:40Z-
dc.date.available2021-12-13T10:19:40Z-
dc.date.issued2019-
dc.identifier.issn1392-1215-
dc.identifier.urihttps://doi.org/10.5755/j01.eie.25.6.24819-
dc.identifier.urihttps://hdl.handle.net/20.500.13091/40-
dc.description.abstractCable termination fault is one of the most important problems for high voltage underground cable lines (HVUCL). Harmonic current (HC) and the sheath current (SC) are causes of cable termination faults of HVUCL. The sheath voltage (SV) of cable increases due to SC and HC also. So, the electroshock risk for human occurs. In this study, cable termination faults are examined for long HVUCL. In literature, solid bonding (SB) and sectional solid bonding (SSB) methods are used to reduce harmonic distortion rate and SC effect in HVUCL. However, when bonding of long HVUCL is made with SB and SSB, the limits of touch voltage and harmonic distortion are exceeded. Therefore, bonding of long HVUCL is made by the modified SSB (MSSB). In MSSB, SV of HVUCL should be known. Thus SV of HVUCL is forecasted by using artificial neural network and hybrid artificial neural networks (HANN) before the long HVUCL is installed. MSSB parameters and HANN are optimized by optimization method. The limits of touch voltage and harmonic distortion are restricted by using MSSB in long HVUCL under high harmonic distortion conditions.en_US
dc.language.isoenen_US
dc.publisherKAUNAS UNIV TECHNOLOGYen_US
dc.relation.ispartofELEKTRONIKA IR ELEKTROTECHNIKAen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBonding Methoden_US
dc.subjectHigh Voltage Cable Terminationen_US
dc.subjectHybrid Artificial Neural Networken_US
dc.subjectInsulation Faulten_US
dc.subjectPower Transmissionen_US
dc.subjectDanish Experienceen_US
dc.subjectSystemsen_US
dc.titleMSSB to Prevent Cable Termination Faults for Long High Voltage Underground Cable Linesen_US
dc.typeArticleen_US
dc.identifier.doi10.5755/j01.eie.25.6.24819-
dc.identifier.scopus2-s2.0-85077438497en_US
dc.departmentFakülteler, Mühendislik ve Doğa Bilimleri Fakültesi, Elektrik-Elektronik Mühendisliği Bölümüen_US
dc.identifier.volume25en_US
dc.identifier.issue6en_US
dc.identifier.startpage8en_US
dc.identifier.endpage14en_US
dc.identifier.wosWOS:000502273100002en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.authorscopusid55364837100-
dc.identifier.scopusqualityQ3-
item.cerifentitytypePublications-
item.grantfulltextopen-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeArticle-
item.fulltextWith Fulltext-
crisitem.author.dept02.04. Department of Electrical and Electronics Engineering-
Appears in Collections:Mühendislik ve Doğa Bilimleri Fakültesi Koleksiyonu
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collections
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collections
Files in This Item:
File SizeFormat 
24819-Article Text-79853-1-10-20191210.pdf945.91 kBAdobe PDFView/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

3
checked on Apr 13, 2024

WEB OF SCIENCETM
Citations

3
checked on Apr 13, 2024

Page view(s)

74
checked on Apr 15, 2024

Download(s)

24
checked on Apr 15, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.