Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/2084
Full metadata record
DC FieldValueLanguage
dc.contributor.authorUlusoy, Serdar-
dc.date.accessioned2022-02-26T20:57:10Z-
dc.date.available2022-02-26T20:57:10Z-
dc.date.issued2020-
dc.identifier.issn2667-8055-
dc.identifier.urihttps://doi.org/10.36306/konjes.722498-
dc.identifier.urihttps://dergipark.org.tr/tr/pub/konjes/issue/57976/722498-
dc.identifier.urihttps://dergipark.org.tr/tr/download/article-file/1058684-
dc.identifier.urihttps://hdl.handle.net/20.500.13091/2084-
dc.descriptionDergiPark: 722498en_US
dc.descriptionkonjesen_US
dc.description.abstractBu çalışmada, yüksek sönümlü kauçuk mesnet modeline aktif kontrol sistemi uygulanarak, hibrid kontrollü taban izolasyonlu sistemlerin darbe tipi titreşim içeren yakın fay etkisi altında davranışı incelenmiştir. Bu kapsamda, yapı tepkimelerindeki değişimin daha iyi irdelenmesi için hibrid kontrollü taban izolasyonlu yapı modelinin etkin titreşim periyodu sırasıyla 2.0, 3.0 ve 4.0 sn. ve her bir periyot için etkin sönüm oranı %20 ve %30 olarak alınmıştır. Taban izolasyonunun bulunduğu kata aktif tendonlar yerleştirilerek, deprem kaydının her adımı için tendonlara uygulanacak kontrol kuvveti ve oluşan yanal ötelemeler hesaplanmıştır. Orantı-İntegral-Türev (PID) kontrolcüsünün kontrol kuvvetine, yapının toplam kütlesine bağlı olarak sınır konulmuştur. Kontrolcünün parametreleri ise öğretim-öğrenme tabanlı algoritma (TLBO) ile belirlenmiştir. Sonuç olarak hibrid kontrollü taban izolasyonlu yapı modellerinde yanal ötelemelerin önemli ölçüde azaldığı tespit edilmiştir.en_US
dc.description.abstractIn this study, active control system is used for the high damping rubber bearing model and the behavior of base isolated hybrid control systems under the near-fault ground motions is investigated.In this context, in order to examine the change of the structure reactions, the effective vibration period and the effective damping rate for each period of base isolated hybrid control systems were taken as 2.0, 3.0 and 4.0 second and 20% and 30%, respectively. By placing the active tendons on the base of structures, the control forces and lateral displacements were calculated for each step of the earthquake record. The control force of the proportional-integral-derivative (PID) controller is limited depending on the total mass of the structure. The parameters of the controller were determined by teaching-learning based algorithm (TLBO). As a result, the lateral displacement of base isolated hybrid control systems is significantly reduced.en_US
dc.language.isotren_US
dc.publisherKonya Technical Universityen_US
dc.relation.ispartofKonya Mühendislik Bilimleri Dergisien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectTaban izolasyonen_US
dc.subjectaktif Kontrolen_US
dc.subjectÖğretme-öğrenme tabanlı algoritmaen_US
dc.subjectBase isolationen_US
dc.subjectActive controlen_US
dc.subjectTeaching- Learning Based Algorithmen_US
dc.titleHİBRİD KONTROLLÜ TABAN İZOLASYONLU SİSTEMLERİN OPTİMİZASYONUen_US
dc.title.alternativeOptımizatıon of Base Isolated Hybrid Control Systemsen_US
dc.typeArticleen_US
dc.identifier.doi10.36306/konjes.722498-
dc.departmentKTÜNen_US
dc.identifier.volume8en_US
dc.identifier.issue4en_US
dc.identifier.startpage812en_US
dc.identifier.endpage827en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Başka Kurum Yazarıen_US
item.languageiso639-1tr-
item.fulltextWith Fulltext-
item.cerifentitytypePublications-
item.openairetypeArticle-
item.grantfulltextopen-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
Appears in Collections:Konya Mühendislik Bilimleri Dergisi
Files in This Item:
File SizeFormat 
10.36306-konjes.722498-1058684.pdf1.6 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

Page view(s)

52
checked on Apr 22, 2024

Download(s)

18
checked on Apr 22, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.