Please use this identifier to cite or link to this item: https://hdl.handle.net/20.500.13091/1505
Title: Dikey eksenli su türbinlerinde art izi bölgesinin sayısal ve deneysel olarak incelenmesi
Other Titles: Numerical and experimental investigation of the wake region of vertical axis water turbine
Authors: Yağmur, Sercan
Advisors: Köse, Faruk
Keywords: Enerji
Energy
Makine Mühendisliği
Mechanical Engineering
Mühendislik Bilimleri
Engineering Sciences
Hidrolik enerji
Hydraulic energy
Sayısal akışkanlar dinamiği
Computational fluids dynamic
Yenilenebilir enerji
Renewable energy
Publisher: Konya Teknik Üniversitesi
Abstract: Dikey eksenli su türbinleri genellikle akıntı enerjisinden elektrik üretmek için kullanılmaktadırlar. Bu türbinlerin en yaygın kullanılanlarından olan Darrieus tipi türbinler, uzun yıllardır rüzgar enerjisinden elektrik üretmek için kullanılırken son yıllarda su akıntı türbini olarak kullanımları da gittikçe artmaktadır. Suyun yoğunluğu, havanınkine kıyasla çok yüksek olduğundan, birim alandan elde edilen su akışının enerjisi de havaya kıyasla çok daha yüksektir. Bundan dolayı daha fazla güç elde etme potansiyeline sahiptir. Darrieus türbinleri, özellikle kanal içi akışlarda konstrüksiyon kolaylıkları ve basit tasarımları nedeniyle hidrokinetik türbin olarak kullanılabilecek en iyi seçeneklerden biridir. Tez kapsamında, deneysel ve HAD yönteminin kullanıldığı araştırmalar, farklı kalınlıktaki; NACA 0012, NACA 0018 ve NACA 0024 ve farklı kamburluktaki NACA 2418 ve NACA 4418 kanat profillerinin kullanıldığı üç kanatlı H-tipi Darrieus türbininin hidrodinamik performansını incelemek için gerçekleştirilmiştir. Çalışmada, literatürde NACA 0018 kanat profilinin kullanıldığı H-tipi Darrieus hidrokinetik türbininin deneysel performans sonuçları kullanılarak HAD yöntemi ile 2-D ve 3-D analizler SST k-? türbülans modeli kullanılarak doğrulanmıştır. Doğrulanan 2-D HAD yöntemi ile farklı kalınlık ve kamburluktaki kanat profili konfigürasyonları için performans ve art izi bölgesindeki akış yapıları karşılaştırılmıştır. Uç hız oranının ?=0.9-1.4 aralığında yapılan 2-D analizlerde maksimum güç katsayısı ?=1.2 uç hız oranında NACA 4418 kanat profilinin kullanıldığı türbin konfigürasyonundan elde edilmiştir. Her bir türbin için maksimum güç katsayısının elde edildiği çalışma noktasında, türbinlerin art izi bölgesindeki akış yapıları karşılaştırıldığında ise NACA 4418 kanat profilinin kullanıldığı türbinde hız geri kazanımının en erken olduğu belirlenmiştir. Hidrokinetik türbin çiftliği uygulamasında birim alandan transfer edilen enerji miktarını arttırmak için hem performansın hem de art izi bölgesinde hız geri kazanımının hızlı olması gerekmektedir. Bu kapsamda 2-D analiz sonuçlarına bağlı olarak NACA 4418 kanat profilinin kullanıldığı türbinin prototip imalatı yapılarak mevcut deney düzeneğine uyarlanmıştır. NACA 4418 profilinin kullanıldığı türbin ?=0.5-1.4 uç hız oranı aralığında 3-D LES türbülans modeli kullanılarak analiz edilmiş ve açık su kanalı içerisinde performans deneyleri tork ölçümü ile yapılmıştır. Serbest akış hızının 0.3m/s olduğu sistemde hem deneysel hem de LES sonuçlarında NACA 4418 profili için maksimum güç katsayısı ?=1.0 uç hız oranında elde edilmiştir. Maksimum güç katsayısının elde edildiği uç hız oranı ?=1.0'da art izi bölgesindeki akış yapısı Parçacık Görüntülemeli Hız Ölçüm (PIV) yöntemi kullanılarak taranmış ve LES türbülans modelinden elde edilen ortalama hız bileşenleri, girdap ve türbülans kinetik enerji sonuçları ile karşılaştırılmıştır. Art izi bölgesindeki akış yapısı incelenen türbinin alt akış yönüne aynı geometrik özelliklerde bir türbin daha yerleştirilerek, iki türbin arasındaki mesafenin, uç hız oranının ve iki türbinin birbirine göre eş/zıt dönüş yönünün ikinci türbinin performansı üzerine etkisi deneysel tork ölçümü ve LES türbülans modelinin kullanıldığı analizlerle incelenmiştir. Elde edilen sonuçlarda iki türbin arasındaki mesafe arttıkça ikinci türbinin performansı artmıştır. İkinci türbin için maksimum güç katsayısı genel olarak uç hız oranının ?=1.0-1.1 aralığında elde edilmiştir. Birinci türbinin art izi bölgesindeki asimetrik akış yapısına bağlı olarak, türbinlerin birbirine göre zıt yönde dönmesi durumunda elde edilen güç katsayısı, eş yönlü dönüşte elde edilen güç katsayısına göre daha yüksek çıkmıştır. Hem deneysel hem de LES sonuçlarında, alt akış bölgesindeki ikinci türbin x/D=11 konumunda iken, eş yönlü dönüşte üst akış bölgesindeki birinci türbininin performansının yaklaşık % 72'sine ulaşırken, bu değer zıt yönlü dönüşte % 78 civarında elde edilmiştir.
Vertical axis water turbines are generally used to generate electricity from current energy. Darrieus type turbines, one of the most widely used of these turbines, have been used to generate electricity from wind energy for many years, and their use as water flow turbines has been increasing in recent years. Since the density of water is very high compared to that of air, the energy of the water flow obtained per unit area is much higher than that of air. Therefore, it has the potential to extract more power. Darrieus turbines are one of the best options to be used as hydrokinetic turbines, especially in open water channel flows, due to their ease of construction and simple design. Within the scope of the thesis, studies in which experimental and CFD methods are used, with different thicknesses; NACA 0012, NACA 0018 and with different camber; NACA 0024 and NACA 2418 and NACA 4418 profiles were used to examine the hydrodynamic performance of a three-bladed H-type Darrieus turbine. In the study, the experimental performance results of the H-type Darrieus hydrokinetic turbine using the NACA 0018 profile in the literature were verified by using the 2-D and 3-D CFD method using the SST k-? turbulence model. Performance and flow structures in the wake region were compared with the validated 2-D HAD method for different thickness and camber blades configurations. In the 2-D analysis with the tip speed ratio ?=0.9-1.4, the maximum power coefficient was obtained from the turbine configuration using the NACA 4418 profile at the tip speed ratio of ?=1.2. The flow structures in the wake region of the turbines were compared at the operating point where the maximum power coefficient was obtained for each turbine, and it was determined that the velocity recovery was the fastest in the turbine where the NACA 4418 blade profile was used. In the application of a hydrokinetic turbine farm, both the performance and the velocity recovery in the wake region must be fast in order to increase the amount of energy transferred from the unit area. In this context, based on the results of the 2-D analysis, the prototype of the turbine using the NACA 4418 profile was manufactured and adapted to our existing experimental setup. The turbine in which NACA 4418 profile is used has been analyzed using 3-D LES turbulence model in the tip speed ratio range of ? = 0.5-1.4 and performance experiments in the open water channel have been performed by dynamic torque measurement. In the system where the free stream velocity is 0.3m/s, the maximum power coefficient for the NACA 4418 profile was obtained at the tip speed ratio of ? = 1.0 in both experimental and LES results. At the tip speed ratio of ? = 1.0, where the maximum power coefficient was obtained, the flow structure in the wake region of turbine was examined with the results obtained from the Particle Image Velocimetry (PIV) method and the LES turbulence model to compare the time-average velocity fields, vorticity patterns and turbulence kinetic energy. A turbine with the same geometric characteristics was placed downstream of the turbine whose flow structure in the wake region was examined. The effect of the streamwise distance between the two turbines, the tip velocity ratio and the co-/counter rotation of the two turbines on the performance of the second turbine was investigated by using experimental torque measurement and the analysis using the LES turbulence model. In the results obtained, as the distance between the two turbines increased, the performance of the second turbine increased. The maximum power coefficient for the second turbine was generally obtained in the range of ? = 1.0-1.1 of the tip speed ratio for all downstream locations. Due to the asymmetric flow structure in the wake of the first turbine, the power coefficient of the second turbine obtained when the turbines rotate in counter-rotating with respect to each other is higher than the power coefficient obtained in the co-rotating arrangement. In both experimental and numerical analysis results, while the second turbine was positioned at x/D=11 in the downstream, it reached approximately 72 % of the performance of the upstream turbine in the co-rotation, while this value increased and was obtained around 78 % in the counter-rotation.
URI: https://tez.yok.gov.tr/UlusalTezMerkezi/TezGoster?key=v7BkNnnepTnbhn8rNR77LdNJkTzOMnafsIKL1XR98L4v_EbVPvLS8sYH2uXPr6kh
https://hdl.handle.net/20.500.13091/1505
Appears in Collections:Mühendislik ve Doğa Bilimleri Fakültesi Koleksiyonu
Tez Koleksiyonu

Files in This Item:
File SizeFormat 
686887.pdf6.53 MBAdobe PDFView/Open
Show full item record



CORE Recommender

Page view(s)

384
checked on Apr 15, 2024

Download(s)

264
checked on Apr 15, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.